1,500 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.32 kW
4.08 kW
El input
0.80 kW
1.36 kW
COP
5.42
3.00
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
dB(A)
41 dB(A)
Sound power level outdoor
dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
202 %
130 %
Prated
5.36 kW
4.08 kW
SCOP
5.13
3.32
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.74 kW
3.61 kW
COP Tj = -7°C
3.15
2.02
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
3.05 kW
2.16 kW
COP Tj = +2°C
4.96
3.21
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
1.99 kW
1.54 kW
COP Tj = +7°C
6.81
4.43
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
1.45 kW
1.29 kW
COP Tj = 12°C
8.94
6.20
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
4.74 kW
3.61 kW
COP Tj = Tbiv
3.15
2.02
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.21 kW
3.91 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.86
1.68
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.15 kW
0.17 kW
Annual energy consumption Qhe
2161 kWh
2542 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
123 %
COP
2.85
Heating up time
3:10 h:min
Standby power input
56.0 W
Reference hot water temperature
56.0 °C
Mixed water at 40°C
255 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.18 kW
5.94 kW
El input
1.19 kW
1.93 kW
COP
5.21
3.07
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
dB(A)
41 dB(A)
Sound power level outdoor
dB(A)
57 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
203 %
139 %
Prated
6.23 kW
5.62 kW
SCOP
5.15
3.54
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.51 kW
4.97 kW
COP Tj = -7°C
3.13
2.12
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
3.30 kW
3.02 kW
COP Tj = +2°C
4.91
3.41
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
2.24 kW
2.00 kW
COP Tj = +7°C
7.11
4.82
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
1.45 kW
1.30 kW
COP Tj = 12°C
8.94
6.32
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
5.51 kW
4.97 kW
COP Tj = Tbiv
3.13
2.12
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.80 kW
5.27 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.70
1.64
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.43 kW
0.35 kW
Annual energy consumption Qhe
2502 kWh
3283 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
123 %
COP
2.85
Heating up time
3:10 h:min
Standby power input
56.0 W
Reference hot water temperature
56.0 °C
Mixed water at 40°C
255 l