Login

Subtype

VERSATI AIO G2 4-6kW

Certificate Holder
Gree Electric Appliances, Inc. of Zhuhai
West Jinji Rd
519070 Qianshan, Zhuhai, Guangdong
China
Registration number
041-K004-10
Certification Body
BRE Global Limited
Subtype title
VERSATI AIO G2 4-6kW
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

1,100 kg

Certification Date
18.01.2022
Testing basis
Heat Pump Keymark Scheme Rules Rev 09
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

GRS-CQ4.0PdG/NhH2-E
Configure model
Model name
GRS-CQ4.0PdG/NhH2-E
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.00 kW

3.60 kW

El input

0.77 kW

1.31 kW

COP

5.19

2.75

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

47 dB(A)

47 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

232 %

154 %

Prated

5.00 kW

4.00 kW

SCOP

5.87

3.92

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

4.80 kW

4.20 kW

COP Tj = +2°C

3.46

2.10

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

3.30 kW

2.60 kW

COP Tj = +7°C

5.57

3.40

Cdh Tj = +7 °C

0.960

0.970

Pdh Tj = 12°C

2.90 kW

2.70 kW

COP Tj = 12°C

7.60

5.55

Cdh Tj = +12 °C

0.930

0.950

Pdh Tj = Tbiv

4.80 kW

4.20 kW

COP Tj = Tbiv

3.46

2.10

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.80 kW

4.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.46

2.10

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

60 °C

60 °C

Poff

25 W

25 W

PTO

25 W

25 W

PSB

25 W

25 W

PCK

25 W

25 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1137 kWh

1365 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

47 dB(A)

47 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

145 %

95 %

Prated

4.00 kW

3.00 kW

SCOP

3.70

2.45

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

2.40 kW

1.90 kW

COP Tj = -7°C

2.68

1.72

Cdh Tj = -7 °C

0.970

0.980

Pdh Tj = +2°C

2.30 kW

1.90 kW

COP Tj = +2°C

5.34

3.41

Cdh Tj = +2 °C

0.940

0.960

Pdh Tj = +7°C

2.70 kW

2.60 kW

COP Tj = +7°C

7.04

5.29

Cdh Tj = +7 °C

0.940

0.950

Pdh Tj = 12°C

2.60 kW

2.90 kW

COP Tj = 12°C

6.90

6.71

Cdh Tj = +12 °C

0.930

0.940

Pdh Tj = Tbiv

3.10 kW

2.70 kW

COP Tj = Tbiv

2.06

1.35

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

2.80 kW

2.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.19

1.35

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

60 °C

60 °C

Poff

25 W

25 W

PTO

25 W

25 W

PSB

25 W

25 W

PCK

25 W

25 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.27 kW

0.70 kW

Annual energy consumption Qhe

2662 kWh

3015 kWh

Pdh Tj = -15°C (if TOL<-20°C)

3.10

2.70

COP Tj = -15°C (if TOL<-20°C)

2.03

1.35

Cdh Tj = -15 °C

0.980

0.990

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

47 dB(A)

47 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

184 %

128 %

Prated

5.00 kW

5.00 kW

SCOP

4.67

3.27

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.60 kW

4.00 kW

COP Tj = -7°C

3.23

2.03

Cdh Tj = -7 °C

0.980

0.990

Pdh Tj = +2°C

2.90 kW

2.60 kW

COP Tj = +2°C

4.59

3.27

Cdh Tj = +2 °C

0.960

0.970

Pdh Tj = +7°C

2.60 kW

2.30 kW

COP Tj = +7°C

6.39

4.30

Cdh Tj = +7 °C

0.940

0.950

Pdh Tj = 12°C

2.80 kW

2.80 kW

COP Tj = 12°C

6.37

6.00

Cdh Tj = +12 °C

0.940

0.950

Pdh Tj = Tbiv

4.60 kW

4.00 kW

COP Tj = Tbiv

3.23

2.03

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.20 kW

3.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.56

1.38

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

60 °C

60 °C

Poff

25 W

25 W

PTO

25 W

25 W

PSB

25 W

25 W

PCK

25 W

25 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.80 kW

1.20 kW

Annual energy consumption Qhe

2216 kWh

3152 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

122 %

COP

2.92

Heating up time

3:39 h:min

Standby power input

31.9 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

228 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

91 %

COP

2.18

Heating up time

4:10 h:min

Standby power input

39.2 W

Reference hot water temperature

52.8 °C

Mixed water at 40°C

226 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

116 %

COP

2.76

Heating up time

3:54 h:min

Standby power input

34.8 W

Reference hot water temperature

52.8 °C

Mixed water at 40°C

226 l

GRS-CQ6.0PdG/NhH2-E
Configure model
Model name
GRS-CQ6.0PdG/NhH2-E
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.00 kW

5.61 kW

El input

1.23 kW

1.93 kW

COP

4.88

2.90

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

47 dB(A)

47 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

232 %

160 %

Prated

5.00 kW

5.00 kW

SCOP

5.87

4.07

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.20 kW

5.10 kW

COP Tj = +2°C

3.53

2.14

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

3.30 kW

3.30 kW

COP Tj = +7°C

5.57

3.49

Cdh Tj = +7 °C

0.960

0.970

Pdh Tj = 12°C

2.90 kW

2.70 kW

COP Tj = 12°C

7.60

5.67

Cdh Tj = +12 °C

0.930

0.950

Pdh Tj = Tbiv

5.20 kW

5.10 kW

COP Tj = Tbiv

3.53

2.14

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.20 kW

5.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.53

2.14

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

60 °C

60 °C

Poff

25 W

25 W

PTO

25 W

25 W

PSB

25 W

25 W

PCK

25 W

25 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1136 kWh

1643 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

47 dB(A)

47 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

145 %

104 %

Prated

4.00 kW

4.00 kW

SCOP

3.70

2.67

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

2.60 kW

2.40 kW

COP Tj = -7°C

2.69

1.83

Cdh Tj = -7 °C

0.970

0.980

Pdh Tj = +2°C

2.30 kW

2.10 kW

COP Tj = +2°C

5.34

3.87

Cdh Tj = +2 °C

0.940

0.950

Pdh Tj = +7°C

2.70 kW

2.50 kW

COP Tj = +7°C

7.04

5.31

Cdh Tj = +7 °C

0.940

0.950

Pdh Tj = 12°C

2.60 kW

2.90 kW

COP Tj = 12°C

6.90

6.73

Cdh Tj = +12 °C

0.930

0.940

Pdh Tj = Tbiv

3.40 kW

3.10 kW

COP Tj = Tbiv

1.98

1.38

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

2.70 kW

2.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.58

1.10

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

60 °C

60 °C

Poff

25 W

25 W

PTO

25 W

25 W

PSB

25 W

25 W

PCK

25 W

25 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.30 kW

1.70 kW

Annual energy consumption Qhe

2674 kWh

3701 kWh

Pdh Tj = -15°C (if TOL<-20°C)

3.40

3.10

COP Tj = -15°C (if TOL<-20°C)

1.98

1.38

Cdh Tj = -15 °C

0.990

0.990

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

47 dB(A)

47 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

182 %

128 %

Prated

6.00 kW

5.00 kW

SCOP

4.62

3.27

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.30 kW

4.00 kW

COP Tj = -7°C

2.81

2.03

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

3.30 kW

2.60 kW

COP Tj = +2°C

4.68

3.27

Cdh Tj = +2 °C

0.960

0.970

Pdh Tj = +7°C

2.60 kW

2.30 kW

COP Tj = +7°C

6.47

4.30

Cdh Tj = +7 °C

0.940

0.950

Pdh Tj = 12°C

2.80 kW

2.80 kW

COP Tj = 12°C

6.39

6.00

Cdh Tj = +12 °C

0.940

0.950

Pdh Tj = Tbiv

5.30 kW

4.00 kW

COP Tj = Tbiv

2.81

2.03

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.20 kW

3.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.56

1.38

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

60 °C

60 °C

Poff

25 W

25 W

PTO

25 W

25 W

PSB

25 W

25 W

PCK

25 W

25 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.80 kW

1.20 kW

Annual energy consumption Qhe

2685 kWh

3152 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

122 %

COP

2.92

Heating up time

3:39 h:min

Standby power input

31.9 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

228 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

91 %

COP

2.18

Heating up time

4:10 h:min

Standby power input

39.2 W

Reference hot water temperature

52.8 °C

Mixed water at 40°C

226 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

116 %

COP

2.76

Heating up time

3:54 h:min

Standby power input

34.8 W

Reference hot water temperature

52.8 °C

Mixed water at 40°C

226 l