1,200 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.40 kW
5.70 kW
El input
1.28 kW
1.97 kW
COP
5.00
2.90
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
2.30 kW
1.43 kW
Cooling capacity
6.50
7.00
EER
2.83
4.88
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
6.50 kW
7.00 kW
SEER
3.95
5.99
Pdc Tj = 35°C
6.50 kW
7.00 kW
EER Tj = 35°C
2.83
4.88
Pdc Tj = 30°C
4.90 kW
5.39 kW
EER Tj = 30°C
3.99
6.65
Cdc Tj = 30 °C
0.990
0.980
Pdc Tj = 25°C
3.10 kW
3.32 kW
EER Tj = 25°C
4.55
4.93
Cdc Tj = 25 °C
0.980
0.980
Pdc Tj = 20°C
1.37 kW
1.78 kW
EER Tj = 20°C
3.96
9.48
Cdc Tj = 20 °C
0.960
0.930
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Annual energy consumption Qce
987 kWh
701 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
57 dB(A)
57 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
177 %
132 %
Prated
6.50 kW
6.00 kW
SCOP
4.50
3.37
Tbiv
-10 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.90 kW
5.50 kW
COP Tj = -7°C
3.16
2.22
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
3.50 kW
3.40 kW
COP Tj = +2°C
4.48
3.37
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
2.30 kW
2.10 kW
COP Tj = +7°C
5.61
4.07
Cdh Tj = +7 °C
0.960
0.970
Pdh Tj = 12°C
2.50 kW
2.50 kW
COP Tj = 12°C
6.92
6.58
Cdh Tj = +12 °C
0.960
0.970
Pdh Tj = Tbiv
6.50 kW
5.50 kW
COP Tj = Tbiv
2.68
2.22
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.50 kW
5.30 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.68
1.82
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.70 kW
Annual energy consumption Qhe
2986 kWh
3679 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
128 %
COP
3.07
Heating up time
01:32 h:min
Standby power input
28.3 W
Reference hot water temperature
54.1 °C
Mixed water at 40°C
255 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.40 kW
5.70 kW
El input
1.28 kW
1.97 kW
COP
5.00
2.90
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
2.30 kW
1.43 kW
Cooling capacity
6.50
7.00
EER
2.83
4.88
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
6.50 kW
7.00 kW
SEER
3.95
5.99
Pdc Tj = 35°C
6.50 kW
7.00 kW
EER Tj = 35°C
2.83
4.88
Pdc Tj = 30°C
4.90 kW
5.39 kW
EER Tj = 30°C
3.99
6.65
Cdc Tj = 30 °C
0.990
0.980
Pdc Tj = 25°C
3.10 kW
3.32 kW
EER Tj = 25°C
4.55
4.93
Cdc Tj = 25 °C
0.980
0.980
Pdc Tj = 20°C
1.37 kW
1.78 kW
EER Tj = 20°C
3.96
9.48
Cdc Tj = 20 °C
0.960
0.930
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Annual energy consumption Qce
987 kWh
701 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
57 dB(A)
57 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
177 %
132 %
Prated
6.50 kW
6.00 kW
SCOP
4.50
3.37
Tbiv
-10 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.90 kW
5.50 kW
COP Tj = -7°C
3.16
2.22
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
3.50 kW
3.40 kW
COP Tj = +2°C
4.48
3.37
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
2.30 kW
2.10 kW
COP Tj = +7°C
5.61
4.07
Cdh Tj = +7 °C
0.960
0.970
Pdh Tj = 12°C
2.50 kW
2.50 kW
COP Tj = 12°C
6.92
6.58
Cdh Tj = +12 °C
0.960
0.970
Pdh Tj = Tbiv
6.50 kW
5.50 kW
COP Tj = Tbiv
2.68
2.22
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.50 kW
5.30 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.68
1.82
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.70 kW
Annual energy consumption Qhe
2986 kWh
3679 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
128 %
COP
3.07
Heating up time
01:32 h:min
Standby power input
28.3 W
Reference hot water temperature
54.1 °C
Mixed water at 40°C
255 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.40 kW
5.70 kW
El input
1.28 kW
1.97 kW
COP
5.00
2.90
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
2.30 kW
1.43 kW
Cooling capacity
6.50
7.00
EER
2.83
4.88
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
6.50 kW
7.00 kW
SEER
3.95
5.99
Pdc Tj = 35°C
6.50 kW
7.00 kW
EER Tj = 35°C
2.83
4.88
Pdc Tj = 30°C
4.90 kW
5.39 kW
EER Tj = 30°C
3.99
6.65
Cdc Tj = 30 °C
0.990
0.980
Pdc Tj = 25°C
3.10 kW
3.32 kW
EER Tj = 25°C
4.55
4.93
Cdc Tj = 25 °C
0.980
0.980
Pdc Tj = 20°C
1.37 kW
1.78 kW
EER Tj = 20°C
3.96
9.48
Cdc Tj = 20 °C
0.960
0.930
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Annual energy consumption Qce
987 kWh
701 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
57 dB(A)
57 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
177 %
132 %
Prated
6.50 kW
6.00 kW
SCOP
4.50
3.37
Tbiv
-10 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.90 kW
5.50 kW
COP Tj = -7°C
3.16
2.22
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
3.50 kW
3.40 kW
COP Tj = +2°C
4.48
3.37
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
2.30 kW
2.10 kW
COP Tj = +7°C
5.61
4.07
Cdh Tj = +7 °C
0.960
0.970
Pdh Tj = 12°C
2.50 kW
2.50 kW
COP Tj = 12°C
6.92
6.58
Cdh Tj = +12 °C
0.960
0.970
Pdh Tj = Tbiv
6.50 kW
5.50 kW
COP Tj = Tbiv
2.68
2.22
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.50 kW
5.30 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.68
1.82
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.70 kW
Annual energy consumption Qhe
2986 kWh
3679 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
M
Efficiency ηDHW
122 %
COP
2.88
Heating up time
01:32 h:min
Standby power input
20.4 W
Reference hot water temperature
54.2 °C
Mixed water at 40°C
261 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.40 kW
5.70 kW
El input
1.28 kW
1.97 kW
COP
5.00
2.90
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
2.30 kW
1.43 kW
Cooling capacity
6.50
7.00
EER
2.83
4.88
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
6.50 kW
7.00 kW
SEER
3.95
5.99
Pdc Tj = 35°C
6.50 kW
7.00 kW
EER Tj = 35°C
2.83
4.88
Pdc Tj = 30°C
4.90 kW
5.39 kW
EER Tj = 30°C
3.99
6.65
Cdc Tj = 30 °C
0.990
0.980
Pdc Tj = 25°C
3.10 kW
3.32 kW
EER Tj = 25°C
4.55
4.93
Cdc Tj = 25 °C
0.980
0.980
Pdc Tj = 20°C
1.37 kW
1.78 kW
EER Tj = 20°C
3.96
9.48
Cdc Tj = 20 °C
0.960
0.930
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Annual energy consumption Qce
987 kWh
701 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
57 dB(A)
57 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
177 %
132 %
Prated
6.50 kW
6.00 kW
SCOP
4.50
3.37
Tbiv
-10 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.90 kW
5.50 kW
COP Tj = -7°C
3.16
2.22
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
3.50 kW
3.40 kW
COP Tj = +2°C
4.48
3.37
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
2.30 kW
2.10 kW
COP Tj = +7°C
5.61
4.07
Cdh Tj = +7 °C
0.960
0.970
Pdh Tj = 12°C
2.50 kW
2.50 kW
COP Tj = 12°C
6.92
6.58
Cdh Tj = +12 °C
0.960
0.970
Pdh Tj = Tbiv
6.50 kW
5.50 kW
COP Tj = Tbiv
2.68
2.22
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.50 kW
5.30 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.68
1.82
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.70 kW
Annual energy consumption Qhe
2986 kWh
3679 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
M
Efficiency ηDHW
122 %
COP
2.88
Heating up time
01:32 h:min
Standby power input
20.4 W
Reference hot water temperature
54.2 °C
Mixed water at 40°C
261 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
7.67 kW
8.18 kW
El input
1.62 kW
2.88 kW
COP
4.73
2.84
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
2.33 kW
1.45 kW
Cooling capacity
6.50
7.10
EER
2.79
4.88
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
6.50 kW
7.10 kW
SEER
4.32
5.82
Pdc Tj = 35°C
6.50 kW
7.10 kW
EER Tj = 35°C
2.79
4.88
Pdc Tj = 30°C
4.97 kW
5.65 kW
EER Tj = 30°C
3.96
6.71
Cdc Tj = 30 °C
0.990
0.990
Pdc Tj = 25°C
3.35 kW
3.18 kW
EER Tj = 25°C
4.74
5.26
Cdc Tj = 25 °C
0.980
0.980
Pdc Tj = 20°C
1.55 kW
1.67 kW
EER Tj = 20°C
5.50
7.40
Cdc Tj = 20 °C
0.950
0.930
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Annual energy consumption Qce
904 kWh
732 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
32 dB(A)
32 dB(A)
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
176 %
125 %
Prated
7.00 kW
7.00 kW
SCOP
4.48
3.21
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
6.06 kW
6.19 kW
COP Tj = -7°C
2.97
1.95
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
4.12 kW
3.79 kW
COP Tj = +2°C
4.46
3.24
Cdh Tj = +2 °C
0.980
0.990
Pdh Tj = +7°C
2.78 kW
2.49 kW
COP Tj = +7°C
5.70
4.10
Cdh Tj = +7 °C
0.970
0.970
Pdh Tj = 12°C
2.67 kW
2.55 kW
COP Tj = 12°C
7.80
6.10
Cdh Tj = +12 °C
0.960
0.960
Pdh Tj = Tbiv
6.06 kW
6.19 kW
COP Tj = Tbiv
2.97
1.95
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.64 kW
4.90 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.58
1.66
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.36 kW
2.10 kW
Annual energy consumption Qhe
3225 kWh
4504 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
125 %
COP
2.99
Heating up time
01:41 h:min
Standby power input
30.0 W
Reference hot water temperature
54.9 °C
Mixed water at 40°C
264 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
7.67 kW
8.18 kW
El input
1.62 kW
2.88 kW
COP
4.73
2.84
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
2.33 kW
1.45 kW
Cooling capacity
6.50
7.10
EER
2.79
4.88
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
6.50 kW
7.10 kW
SEER
4.32
5.82
Pdc Tj = 35°C
6.50 kW
7.10 kW
EER Tj = 35°C
2.79
4.88
Pdc Tj = 30°C
4.97 kW
5.65 kW
EER Tj = 30°C
3.96
6.71
Cdc Tj = 30 °C
0.990
0.990
Pdc Tj = 25°C
3.35 kW
3.18 kW
EER Tj = 25°C
4.74
5.26
Cdc Tj = 25 °C
0.980
0.980
Pdc Tj = 20°C
1.55 kW
1.67 kW
EER Tj = 20°C
5.50
7.40
Cdc Tj = 20 °C
0.950
0.930
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Annual energy consumption Qce
904 kWh
732 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
32 dB(A)
32 dB(A)
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
176 %
125 %
Prated
7.00 kW
7.00 kW
SCOP
4.48
3.21
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
6.06 kW
6.19 kW
COP Tj = -7°C
2.97
1.95
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
4.12 kW
3.79 kW
COP Tj = +2°C
4.46
3.24
Cdh Tj = +2 °C
0.980
0.990
Pdh Tj = +7°C
2.78 kW
2.49 kW
COP Tj = +7°C
5.70
4.10
Cdh Tj = +7 °C
0.970
0.970
Pdh Tj = 12°C
2.67 kW
2.55 kW
COP Tj = 12°C
7.80
6.10
Cdh Tj = +12 °C
0.960
0.960
Pdh Tj = Tbiv
6.06 kW
6.19 kW
COP Tj = Tbiv
2.97
1.95
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.64 kW
4.90 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.58
1.66
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.36 kW
2.10 kW
Annual energy consumption Qhe
3225 kWh
4504 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
125 %
COP
2.99
Heating up time
01:41 h:min
Standby power input
30.0 W
Reference hot water temperature
54.9 °C
Mixed water at 40°C
264 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
7.67 kW
8.18 kW
El input
1.62 kW
2.88 kW
COP
4.73
2.84
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
2.33 kW
1.45 kW
Cooling capacity
6.50
7.10
EER
2.79
4.88
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
6.50 kW
7.10 kW
SEER
4.32
5.82
Pdc Tj = 35°C
6.50 kW
7.10 kW
EER Tj = 35°C
2.79
4.88
Pdc Tj = 30°C
4.97 kW
5.65 kW
EER Tj = 30°C
3.96
6.71
Cdc Tj = 30 °C
0.990
0.990
Pdc Tj = 25°C
3.35 kW
3.18 kW
EER Tj = 25°C
4.74
5.26
Cdc Tj = 25 °C
0.980
0.980
Pdc Tj = 20°C
1.55 kW
1.67 kW
EER Tj = 20°C
5.50
7.40
Cdc Tj = 20 °C
0.950
0.930
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Annual energy consumption Qce
904 kWh
732 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
32 dB(A)
32 dB(A)
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
176 %
125 %
Prated
7.00 kW
7.00 kW
SCOP
4.48
3.21
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
6.06 kW
6.19 kW
COP Tj = -7°C
2.97
1.95
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
4.12 kW
3.79 kW
COP Tj = +2°C
4.46
3.24
Cdh Tj = +2 °C
0.980
0.990
Pdh Tj = +7°C
2.78 kW
2.49 kW
COP Tj = +7°C
5.70
4.10
Cdh Tj = +7 °C
0.970
0.970
Pdh Tj = 12°C
2.67 kW
2.55 kW
COP Tj = 12°C
7.80
6.10
Cdh Tj = +12 °C
0.960
0.960
Pdh Tj = Tbiv
6.06 kW
6.19 kW
COP Tj = Tbiv
2.97
1.95
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.64 kW
4.90 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.58
1.66
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.36 kW
2.10 kW
Annual energy consumption Qhe
3225 kWh
4504 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
M
Efficiency ηDHW
121 %
COP
2.84
Heating up time
01:41 h:min
Standby power input
22.0 W
Reference hot water temperature
55.2 °C
Mixed water at 40°C
272 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
7.67 kW
8.18 kW
El input
1.62 kW
2.88 kW
COP
4.73
2.84
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
2.33 kW
1.45 kW
Cooling capacity
6.50
7.10
EER
2.79
4.88
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
6.50 kW
7.10 kW
SEER
4.32
5.82
Pdc Tj = 35°C
6.50 kW
7.10 kW
EER Tj = 35°C
2.79
4.88
Pdc Tj = 30°C
4.97 kW
5.65 kW
EER Tj = 30°C
3.96
6.71
Cdc Tj = 30 °C
0.990
0.990
Pdc Tj = 25°C
3.35 kW
3.18 kW
EER Tj = 25°C
4.74
5.26
Cdc Tj = 25 °C
0.980
0.980
Pdc Tj = 20°C
1.55 kW
1.67 kW
EER Tj = 20°C
5.50
7.40
Cdc Tj = 20 °C
0.950
0.930
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Annual energy consumption Qce
904 kWh
732 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
32 dB(A)
32 dB(A)
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
176 %
125 %
Prated
7.00 kW
7.00 kW
SCOP
4.48
3.21
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
6.06 kW
6.19 kW
COP Tj = -7°C
2.97
1.95
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
4.12 kW
3.79 kW
COP Tj = +2°C
4.46
3.24
Cdh Tj = +2 °C
0.980
0.990
Pdh Tj = +7°C
2.78 kW
2.49 kW
COP Tj = +7°C
5.70
4.10
Cdh Tj = +7 °C
0.970
0.970
Pdh Tj = 12°C
2.67 kW
2.55 kW
COP Tj = 12°C
7.80
6.10
Cdh Tj = +12 °C
0.960
0.960
Pdh Tj = Tbiv
6.06 kW
6.19 kW
COP Tj = Tbiv
2.97
1.95
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.64 kW
4.90 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.58
1.66
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.36 kW
2.10 kW
Annual energy consumption Qhe
3225 kWh
4504 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
M
Efficiency ηDHW
121 %
COP
2.84
Heating up time
01:41 h:min
Standby power input
22.0 W
Reference hot water temperature
55.2 °C
Mixed water at 40°C
272 l