Login

Subtype

S2125-8

Certificate Holder
Nibe AB
Box 14
S-28521 Markaryd
Sweden
Registration number
012-C700114 / Issue 1
Certification Body
RISE CERT
Subtype title
S2125-8
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

0,800 kg

Certification Date
30.12.2021
Testing basis
EN 14511:2018, EN 14825:2018, EN 12102:2017
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

S2125-8 3x400V
Configure model
Model name
S2125-8 3x400V
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.22 kW

7.02 kW

El input

1.03 kW

2.22 kW

COP

5.07

3.17

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

49 dB(A)

49 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

161 %

123 %

Prated

5.40 kW

5.20 kW

SCOP

4.11

3.16

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

3.25 kW

3.16 kW

COP Tj = -7°C

3.04

2.42

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

1.98 kW

1.95 kW

COP Tj = +2°C

5.25

3.82

Cdh Tj = +2 °C

0.970

0.980

Pdh Tj = +7°C

2.24 kW

2.46 kW

COP Tj = +7°C

6.65

5.32

Cdh Tj = +7 °C

0.960

0.970

Pdh Tj = 12°C

2.41 kW

2.40 kW

COP Tj = 12°C

7.44

6.10

Cdh Tj = +12 °C

0.960

0.970

Pdh Tj = Tbiv

4.44 kW

4.25 kW

COP Tj = Tbiv

2.80

2.20

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.63 kW

3.34 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.34

1.69

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

65 °C

65 °C

Poff

8 W

8 W

PTO

13 W

13 W

PSB

11 W

11 W

PCK

5 W

5 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

1.80 kW

1.90 kW

Annual energy consumption Qhe

3238 kWh

4055 kWh

Pdh Tj = -15°C (if TOL<-20°C)

4.44

4.25

COP Tj = -15°C (if TOL<-20°C)

2.80

2.20

Cdh Tj = -15 °C

0.990

0.990

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

49 dB(A)

49 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

196 %

146 %

Prated

5.30 kW

5.30 kW

SCOP

4.99

3.73

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.25 kW

4.57 kW

COP Tj = -7°C

2.90

2.19

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

3.12 kW

2.80 kW

COP Tj = +2°C

5.08

3.77

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

2.44 kW

2.05 kW

COP Tj = +7°C

6.49

4.75

Cdh Tj = +7 °C

0.970

0.970

Pdh Tj = 12°C

2.47 kW

2.30 kW

COP Tj = 12°C

7.36

5.70

Cdh Tj = +12 °C

0.960

0.970

Pdh Tj = Tbiv

5.02 kW

4.82 kW

COP Tj = Tbiv

2.98

2.21

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.02 kW

4.82 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.98

2.21

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

65 °C

65 °C

Poff

8 W

8 W

PTO

13 W

13 W

PSB

11 W

11 W

PCK

5 W

5 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.28 kW

0.48 kW

Annual energy consumption Qhe

2196 kWh

2939 kWh

S2125-8 1x230V
Configure model
Model name
S2125-8 1x230V
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.22 kW

7.02 kW

El input

1.03 kW

2.22 kW

COP

5.07

3.17

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

49 dB(A)

49 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

161 %

123 %

Prated

5.40 kW

5.20 kW

SCOP

4.11

3.16

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

3.25 kW

3.16 kW

COP Tj = -7°C

3.04

2.42

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

1.98 kW

1.95 kW

COP Tj = +2°C

5.25

3.82

Cdh Tj = +2 °C

0.970

0.980

Pdh Tj = +7°C

2.24 kW

2.46 kW

COP Tj = +7°C

6.65

5.32

Cdh Tj = +7 °C

0.960

0.970

Pdh Tj = 12°C

2.41 kW

2.40 kW

COP Tj = 12°C

7.44

6.10

Cdh Tj = +12 °C

0.960

0.970

Pdh Tj = Tbiv

4.44 kW

4.25 kW

COP Tj = Tbiv

2.80

2.20

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.63 kW

3.34 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.34

1.69

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

65 °C

65 °C

Poff

8 W

8 W

PTO

13 W

13 W

PSB

11 W

11 W

PCK

5 W

5 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

1.80 kW

1.90 kW

Annual energy consumption Qhe

3238 kWh

4055 kWh

Pdh Tj = -15°C (if TOL<-20°C)

4.44

4.25

COP Tj = -15°C (if TOL<-20°C)

2.80

2.20

Cdh Tj = -15 °C

0.990

0.990

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

49 dB(A)

49 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

196 %

146 %

Prated

5.30 kW

5.30 kW

SCOP

4.99

3.73

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.25 kW

4.57 kW

COP Tj = -7°C

2.90

2.19

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

3.12 kW

2.80 kW

COP Tj = +2°C

5.08

3.77

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

2.44 kW

2.05 kW

COP Tj = +7°C

6.49

4.75

Cdh Tj = +7 °C

0.970

0.970

Pdh Tj = 12°C

2.47 kW

2.30 kW

COP Tj = 12°C

7.36

5.70

Cdh Tj = +12 °C

0.960

0.970

Pdh Tj = Tbiv

5.02 kW

4.82 kW

COP Tj = Tbiv

2.98

2.21

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.02 kW

4.82 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.98

2.21

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

65 °C

65 °C

Poff

8 W

8 W

PTO

13 W

13 W

PSB

11 W

11 W

PCK

5 W

5 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.28 kW

0.48 kW

Annual energy consumption Qhe

2196 kWh

2939 kWh