2,800 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
18 kW
15.3 kW
El input
3.77 kW
4.86 kW
COP
4.79
3.15
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
61.6 dB(A)
61.6 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
181 %
142 %
Prated
12.80 kW
12.20 kW
SCOP
4.61
3.64
Tbiv
-9 °C
-8 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
12.00 kW
12.80 kW
COP Tj = -7°C
3.06
2.34
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
7.70 kW
7.43 kW
COP Tj = +2°C
4.61
3.61
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
9.20 kW
9.11 kW
COP Tj = +7°C
6.75
5.21
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
6.20 kW
6.10 kW
COP Tj = 12°C
9.64
8.12
Cdh Tj = +12 °C
0.990
0.990
Pdh Tj = Tbiv
11.64 kW
10.76 kW
COP Tj = Tbiv
3.08
2.12
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.40 kW
9.57 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.24
2.15
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
60 °C
60 °C
Poff
100 W
100 W
PTO
40 W
40 W
PSB
100 W
100 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.40 kW
2.63 kW
Annual energy consumption Qhe
5731 kWh
6931 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
99 %
COP
2.4
Heating up time
00:49 h:min
Standby power input
27.5 W
Reference hot water temperature
49.42 °C
Mixed water at 40°C
279.21 l