Login

Subtype

Grant Aerona3 HPID17R32

Certificate Holder
Grant Engineering (Ireland) ULC
Barrack St
R42 D788 Ballinree, Birr
Ireland
Registration number
041-K005-04
Certification Body
BRE Global Limited
Subtype title
Grant Aerona3 HPID17R32
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

2,800 kg

Certification Date
01.03.2022
Testing basis
Heat Pump Keymark Scheme Rules Rev 09
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

HPID17R32
Configure model
Model name
HPID17R32
Application
Heating + DHW + low temp
Units
Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

18 kW

15.3 kW

El input

3.77 kW

4.86 kW

COP

4.79

3.15

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

61.6 dB(A)

61.6 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

181 %

142 %

Prated

12.80 kW

12.20 kW

SCOP

4.61

3.64

Tbiv

-9 °C

-8 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.00 kW

12.80 kW

COP Tj = -7°C

3.06

2.34

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

7.70 kW

7.43 kW

COP Tj = +2°C

4.61

3.61

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

9.20 kW

9.11 kW

COP Tj = +7°C

6.75

5.21

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.20 kW

6.10 kW

COP Tj = 12°C

9.64

8.12

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

11.64 kW

10.76 kW

COP Tj = Tbiv

3.08

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.40 kW

9.57 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.24

2.15

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

60 °C

60 °C

Poff

100 W

100 W

PTO

40 W

40 W

PSB

100 W

100 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.40 kW

2.63 kW

Annual energy consumption Qhe

5731 kWh

6931 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

99 %

COP

2.4

Heating up time

00:49 h:min

Standby power input

27.5 W

Reference hot water temperature

49.42 °C

Mixed water at 40°C

279.21 l