2,990 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
7.97 kW
7.08 kW
El input
1.92 kW
3.05 kW
COP
4.15
2.32
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
46 dB(A)
46 dB(A)
Sound power level outdoor
69 dB(A)
69 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
151 %
111 %
Prated
6.59 kW
5.76 kW
SCOP
3.85
2.84
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.83 kW
5.10 kW
COP Tj = -7°C
2.45
1.66
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
3.33 kW
3.07 kW
COP Tj = +2°C
3.80
2.79
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
2.16 kW
2.10 kW
COP Tj = +7°C
4.96
3.81
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
2.13 kW
1.79 kW
COP Tj = 12°C
6.64
5.55
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
5.83 kW
5.10 kW
COP Tj = Tbiv
2.45
1.66
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.97 kW
4.33 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.08
1.32
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
55 °C
55 °C
Poff
5 W
5 W
PTO
8 W
8 W
PSB
5 W
5 W
PCK
35 W
35 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.62 kW
1.43 kW
Annual energy consumption Qhe
3541 kWh
4184 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
90 %
COP
2.21
Heating up time
3:11 h:min
Standby power input
47.0 W
Reference hot water temperature
47.0 °C
Mixed water at 40°C
364 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
7.97 kW
7.08 kW
El input
1.92 kW
3.05 kW
COP
4.15
2.32
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
46 dB(A)
46 dB(A)
Sound power level outdoor
69 dB(A)
69 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
151 %
111 %
Prated
6.59 kW
5.76 kW
SCOP
3.85
2.84
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.83 kW
5.10 kW
COP Tj = -7°C
2.45
1.66
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
3.33 kW
3.07 kW
COP Tj = +2°C
3.80
2.79
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
2.16 kW
2.10 kW
COP Tj = +7°C
4.96
3.81
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
2.13 kW
1.79 kW
COP Tj = 12°C
6.64
5.55
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
5.83 kW
5.10 kW
COP Tj = Tbiv
2.45
1.66
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.97 kW
4.33 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.08
1.32
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
55 °C
55 °C
Poff
5 W
5 W
PTO
8 W
8 W
PSB
5 W
5 W
PCK
35 W
35 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.62 kW
1.43 kW
Annual energy consumption Qhe
3541 kWh
4184 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
90 %
COP
2.21
Heating up time
3:11 h:min
Standby power input
47.0 W
Reference hot water temperature
47.0 °C
Mixed water at 40°C
364 l