Login

Subtype

Bosch Compress 7000iAW 5 OR, Compress 6000 AW-5, Bosch CS7001iAW 5

Certificate Holder
Bosch Thermotechnik GmbH
Junkersstraße 20 - 24
73249 Wernau
Germany
Registration number
011-1W0122
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Bosch Compress 7000iAW 5 OR, Compress 6000 AW-5, Bosch CS7001iAW 5
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R410A
Mass of Refrigerant

1,700 kg

Certification Date
18.07.2017
Testing basis
HP KEYMARK certification scheme rules rev. 8
Generate PDF Export model CSV
  • Number of models 14

Models

Bosch CS7000iAW 5 ORMS-S
Configure model
Model name
Bosch CS7000iAW 5 ORMS-S
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

2.14 kW

1.88 kW

El input

0.46 kW

0.72 kW

COP

4.68

2.60

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

25 dB(A)

25 dB(A)

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

224 %

161 %

Prated

5.30 kW

5.60 kW

SCOP

5.69

4.10

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.28 kW

5.65 kW

COP Tj = +2°C

3.08

2.22

Pdh Tj = +7°C

3.22 kW

3.92 kW

COP Tj = +7°C

5.31

3.54

Pdh Tj = 12°C

1.50 kW

2.49 kW

COP Tj = 12°C

6.79

5.35

Pdh Tj = Tbiv

5.28 kW

5.65 kW

COP Tj = Tbiv

3.08

2.22

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.28 kW

5.65 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.08

2.22

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

22 W

22 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1245 kWh

1823 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

25 dB(A)

25 dB(A)

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

159 %

117 %

Prated

3.90 kW

4.00 kW

SCOP

4.04

3.00

Tbiv

-17 °C

-16 °C

TOL

-20 °C

-18 °C

Pdh Tj = -7°C

2.46 kW

2.32 kW

COP Tj = -7°C

3.56

2.57

Pdh Tj = +2°C

1.48 kW

1.79 kW

COP Tj = +2°C

4.86

3.66

Pdh Tj = +7°C

1.13 kW

2.13 kW

COP Tj = +7°C

5.53

4.54

Pdh Tj = 12°C

1.21 kW

2.55 kW

COP Tj = 12°C

5.75

5.82

Pdh Tj = Tbiv

3.43 kW

3.37 kW

COP Tj = Tbiv

2.36

1.78

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.08 kW

3.11 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.16

1.61

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

22 W

22 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.90 kW

4.00 kW

Annual energy consumption Qhe

2378 kWh

3287 kWh

Pdh Tj = -15°C (if TOL<-20°C)

3.27

1.88

COP Tj = -15°C (if TOL<-20°C)

2.55

1.88

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

25 dB(A)

25 dB(A)

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

183 %

131 %

Prated

4.40 kW

4.10 kW

SCOP

4.65

3.34

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.88 kW

3.57 kW

COP Tj = -7°C

3.07

2.16

Pdh Tj = +2°C

2.51 kW

2.34 kW

COP Tj = +2°C

4.69

3.29

Pdh Tj = +7°C

1.50 kW

2.13 kW

COP Tj = +7°C

5.78

4.29

Pdh Tj = 12°C

1.23 kW

2.52 kW

COP Tj = 12°C

6.13

5.53

Pdh Tj = Tbiv

4.37 kW

4.05 kW

COP Tj = Tbiv

2.76

1.85

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.37 kW

4.05 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.76

1.85

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

22 W

22 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1955 kWh

2533 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

119 %

COP

2.80

Heating up time

03:00 h:min

Standby power input

47.0 W

Reference hot water temperature

54.2 °C

Mixed water at 40°C

272 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

81 %

COP

1.90

Heating up time

04:18 h:min

Standby power input

65.0 W

Reference hot water temperature

52.4 °C

Mixed water at 40°C

275 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

96 %

COP

2.25

Heating up time

03:30 h:min

Standby power input

55.0 W

Reference hot water temperature

52.1 °C

Mixed water at 40°C

272 l

Bosch CS7000iAW 5 ORM-S
Configure model
Model name
Bosch CS7000iAW 5 ORM-S
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

2.14 kW

1.88 kW

El input

0.46 kW

0.72 kW

COP

4.68

2.60

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

25 dB(A)

25 dB(A)

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

224 %

161 %

Prated

5.30 kW

5.60 kW

SCOP

5.69

4.10

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.28 kW

5.65 kW

COP Tj = +2°C

3.08

2.22

Pdh Tj = +7°C

3.22 kW

3.92 kW

COP Tj = +7°C

5.31

3.54

Pdh Tj = 12°C

1.50 kW

2.49 kW

COP Tj = 12°C

6.79

5.35

Pdh Tj = Tbiv

5.28 kW

5.65 kW

COP Tj = Tbiv

3.08

2.22

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.28 kW

5.65 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.08

2.22

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

22 W

22 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1245 kWh

1823 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

25 dB(A)

25 dB(A)

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

159 %

117 %

Prated

3.90 kW

4.00 kW

SCOP

4.04

3.00

Tbiv

-17 °C

-16 °C

TOL

-20 °C

-18 °C

Pdh Tj = -7°C

2.46 kW

2.32 kW

COP Tj = -7°C

3.56

2.57

Pdh Tj = +2°C

1.48 kW

1.79 kW

COP Tj = +2°C

4.86

3.66

Pdh Tj = +7°C

1.13 kW

2.13 kW

COP Tj = +7°C

5.53

4.54

Pdh Tj = 12°C

1.21 kW

2.55 kW

COP Tj = 12°C

5.75

5.82

Pdh Tj = Tbiv

3.43 kW

3.37 kW

COP Tj = Tbiv

2.36

1.78

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.08 kW

3.11 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.16

1.61

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

22 W

22 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.90 kW

4.00 kW

Annual energy consumption Qhe

2378 kWh

3287 kWh

Pdh Tj = -15°C (if TOL<-20°C)

3.27

1.88

COP Tj = -15°C (if TOL<-20°C)

2.55

1.88

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

25 dB(A)

25 dB(A)

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

183 %

131 %

Prated

4.40 kW

4.10 kW

SCOP

4.65

3.34

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.88 kW

3.57 kW

COP Tj = -7°C

3.07

2.16

Pdh Tj = +2°C

2.51 kW

2.34 kW

COP Tj = +2°C

4.69

3.29

Pdh Tj = +7°C

1.50 kW

2.13 kW

COP Tj = +7°C

5.78

4.29

Pdh Tj = 12°C

1.23 kW

2.52 kW

COP Tj = 12°C

6.13

5.53

Pdh Tj = Tbiv

4.37 kW

4.05 kW

COP Tj = Tbiv

2.76

1.85

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.37 kW

4.05 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.76

1.85

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

22 W

22 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1955 kWh

2533 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

119 %

COP

2.80

Heating up time

03:00 h:min

Standby power input

47.0 W

Reference hot water temperature

54.2 °C

Mixed water at 40°C

272 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

81 %

COP

1.90

Heating up time

04:18 h:min

Standby power input

65.0 W

Reference hot water temperature

52.4 °C

Mixed water at 40°C

275 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

96 %

COP

2.25

Heating up time

03:30 h:min

Standby power input

55.0 W

Reference hot water temperature

52.1 °C

Mixed water at 40°C

272 l

Bosch CS7000iAW 5 ORB-S
Configure model
Model name
Bosch CS7000iAW 5 ORB-S
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

2.14 kW

1.88 kW

El input

0.46 kW

0.72 kW

COP

4.68

2.60

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

29 dB(A)

29 dB(A)

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

224 %

161 %

Prated

5.30 kW

5.60 kW

SCOP

5.69

4.10

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.28 kW

5.65 kW

COP Tj = +2°C

3.08

2.22

Pdh Tj = +7°C

3.22 kW

3.92 kW

COP Tj = +7°C

5.31

3.54

Pdh Tj = 12°C

1.50 kW

2.49 kW

COP Tj = 12°C

6.79

5.35

Pdh Tj = Tbiv

5.28 kW

5.65 kW

COP Tj = Tbiv

3.08

2.22

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.28 kW

5.65 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.08

2.22

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

22 W

22 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1245 kWh

1823 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

29 dB(A)

29 dB(A)

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

159 %

117 %

Prated

3.90 kW

4.00 kW

SCOP

4.04

3.00

Tbiv

-17 °C

-16 °C

TOL

-20 °C

-18 °C

Pdh Tj = -7°C

2.46 kW

2.32 kW

COP Tj = -7°C

3.56

2.57

Pdh Tj = +2°C

1.48 kW

1.79 kW

COP Tj = +2°C

4.86

3.66

Pdh Tj = +7°C

1.13 kW

2.13 kW

COP Tj = +7°C

5.53

4.54

Pdh Tj = 12°C

1.21 kW

2.55 kW

COP Tj = 12°C

5.75

5.82

Pdh Tj = Tbiv

3.43 kW

3.37 kW

COP Tj = Tbiv

2.36

1.78

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.08 kW

3.11 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.16

1.61

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

22 W

22 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2378 kWh

3287 kWh

Pdh Tj = -15°C (if TOL<-20°C)

3.27

1.88

COP Tj = -15°C (if TOL<-20°C)

2.55

1.88

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

29 dB(A)

29 dB(A)

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

183 %

131 %

Prated

4.40 kW

4.10 kW

SCOP

4.65

3.34

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.88 kW

3.57 kW

COP Tj = -7°C

3.07

2.16

Cdh Tj = -7 °C

1.00

1.00

Pdh Tj = +2°C

2.51 kW

2.34 kW

COP Tj = +2°C

4.69

3.29

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

1.50 kW

2.13 kW

COP Tj = +7°C

5.78

4.29

Cdh Tj = +7 °C

1.00

1.00

Pdh Tj = 12°C

1.23 kW

2.52 kW

COP Tj = 12°C

6.13

5.53

Cdh Tj = +12 °C

1.00

1.00

Pdh Tj = Tbiv

4.37 kW

4.05 kW

COP Tj = Tbiv

2.76

1.85

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.37 kW

4.05 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.76

1.85

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

22 W

22 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1955 kWh

2533 kWh

Bosch CS7000iAW 5 ORE-S
Configure model
Model name
Bosch CS7000iAW 5 ORE-S
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

2.14 kW

1.88 kW

El input

0.46 kW

0.72 kW

COP

4.68

2.60

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

29 dB(A)

29 dB(A)

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

224 %

161 %

Prated

5.30 kW

5.60 kW

SCOP

5.69

4.10

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.28 kW

5.65 kW

COP Tj = +2°C

3.08

2.22

Pdh Tj = +7°C

3.22 kW

3.92 kW

COP Tj = +7°C

5.31

3.54

Pdh Tj = 12°C

1.50 kW

2.49 kW

COP Tj = 12°C

6.79

5.35

Pdh Tj = Tbiv

5.28 kW

5.65 kW

COP Tj = Tbiv

3.08

2.22

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.28 kW

5.65 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.08

2.22

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

22 W

22 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1245 kWh

1823 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

29 dB(A)

29 dB(A)

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

159 %

117 %

Prated

3.90 kW

4.00 kW

SCOP

4.04

3.00

Tbiv

-17 °C

-16 °C

TOL

-20 °C

-18 °C

Pdh Tj = -7°C

2.46 kW

2.32 kW

COP Tj = -7°C

3.56

2.57

Pdh Tj = +2°C

1.48 kW

1.79 kW

COP Tj = +2°C

4.86

3.66

Pdh Tj = +7°C

1.13 kW

2.13 kW

COP Tj = +7°C

5.53

4.54

Pdh Tj = 12°C

1.21 kW

2.55 kW

COP Tj = 12°C

5.75

5.82

Pdh Tj = Tbiv

3.43 kW

3.37 kW

COP Tj = Tbiv

2.36

1.78

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.08 kW

3.11 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.16

1.61

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

22 W

22 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.90 kW

4.00 kW

Annual energy consumption Qhe

2378 kWh

3287 kWh

Pdh Tj = -15°C (if TOL<-20°C)

3.27

1.88

COP Tj = -15°C (if TOL<-20°C)

2.55

1.88

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

29 dB(A)

29 dB(A)

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

183 %

131 %

Prated

4.40 kW

4.10 kW

SCOP

4.65

3.34

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.88 kW

3.57 kW

COP Tj = -7°C

3.07

2.16

Pdh Tj = +2°C

2.51 kW

2.34 kW

COP Tj = +2°C

4.69

3.29

Pdh Tj = +7°C

1.50 kW

2.13 kW

COP Tj = +7°C

5.78

4.29

Pdh Tj = 12°C

1.23 kW

2.52 kW

COP Tj = 12°C

6.13

5.53

Pdh Tj = Tbiv

4.37 kW

4.05 kW

COP Tj = Tbiv

2.76

1.85

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.37 kW

4.05 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.76

1.85

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

22 W

22 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1955 kWh

2533 kWh

Bosch Compress 6000 AW-5 AWE
Configure model
Model name
Bosch Compress 6000 AW-5 AWE
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

2.14 kW

1.88 kW

El input

0.46 kW

0.72 kW

COP

4.68

2.60

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

29 dB(A)

29 dB(A)

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

224 %

161 %

Prated

5.30 kW

5.60 kW

SCOP

5.69

4.10

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.28 kW

5.65 kW

COP Tj = +2°C

3.08

2.22

Pdh Tj = +7°C

3.22 kW

3.92 kW

COP Tj = +7°C

5.31

3.54

Pdh Tj = 12°C

1.50 kW

2.49 kW

COP Tj = 12°C

6.79

5.35

Pdh Tj = Tbiv

5.28 kW

5.65 kW

COP Tj = Tbiv

3.08

2.22

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.28 kW

5.65 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.08

2.22

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

22 W

22 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1245 kWh

1823 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

29 dB(A)

29 dB(A)

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

159 %

117 %

Prated

3.90 kW

4.00 kW

SCOP

4.04

3.00

Tbiv

-17 °C

-16 °C

TOL

-20 °C

-18 °C

Pdh Tj = -7°C

2.46 kW

2.32 kW

COP Tj = -7°C

3.56

2.57

Pdh Tj = +2°C

1.48 kW

1.79 kW

COP Tj = +2°C

4.86

3.66

Pdh Tj = +7°C

1.13 kW

2.13 kW

COP Tj = +7°C

5.53

4.54

Pdh Tj = 12°C

1.21 kW

2.55 kW

COP Tj = 12°C

5.75

5.82

Pdh Tj = Tbiv

3.43 kW

3.37 kW

COP Tj = Tbiv

2.36

1.78

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.08 kW

3.11 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.16

1.61

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

22 W

22 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.90 kW

4.00 kW

Annual energy consumption Qhe

2378 kWh

3287 kWh

Pdh Tj = -15°C (if TOL<-20°C)

3.27

1.88

COP Tj = -15°C (if TOL<-20°C)

2.55

1.88

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

29 dB(A)

29 dB(A)

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

183 %

131 %

Prated

4.40 kW

4.10 kW

SCOP

4.65

3.34

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.88 kW

3.57 kW

COP Tj = -7°C

3.07

2.16

Pdh Tj = +2°C

2.51 kW

2.34 kW

COP Tj = +2°C

4.69

3.29

Pdh Tj = +7°C

1.50 kW

2.13 kW

COP Tj = +7°C

5.78

4.29

Pdh Tj = 12°C

1.23 kW

2.52 kW

COP Tj = 12°C

6.13

5.53

Pdh Tj = Tbiv

4.37 kW

4.05 kW

COP Tj = Tbiv

2.76

1.85

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.37 kW

4.05 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.76

1.85

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

22 W

22 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1955 kWh

2533 kWh

Bosch Compress 6000 AW-5 AWB
Configure model
Model name
Bosch Compress 6000 AW-5 AWB
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

2.14 kW

1.88 kW

El input

0.46 kW

0.72 kW

COP

4.68

2.60

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

29 dB(A)

29 dB(A)

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

224 %

161 %

Prated

5.30 kW

5.60 kW

SCOP

5.69

4.10

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.28 kW

5.65 kW

COP Tj = +2°C

3.08

2.22

Pdh Tj = +7°C

3.22 kW

3.92 kW

COP Tj = +7°C

5.31

3.54

Pdh Tj = 12°C

1.50 kW

2.49 kW

COP Tj = 12°C

6.79

5.35

Pdh Tj = Tbiv

5.28 kW

5.65 kW

COP Tj = Tbiv

3.08

2.22

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.28 kW

5.65 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.08

2.22

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

22 W

22 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1245 kWh

1823 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

29 dB(A)

29 dB(A)

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

159 %

117 %

Prated

3.90 kW

4.00 kW

SCOP

4.04

3.00

Tbiv

-17 °C

-16 °C

TOL

-20 °C

-18 °C

Pdh Tj = -7°C

2.46 kW

2.32 kW

COP Tj = -7°C

3.56

2.57

Pdh Tj = +2°C

1.48 kW

1.79 kW

COP Tj = +2°C

4.86

3.66

Pdh Tj = +7°C

1.13 kW

2.13 kW

COP Tj = +7°C

5.53

4.54

Pdh Tj = 12°C

1.21 kW

2.55 kW

COP Tj = 12°C

5.75

5.82

Pdh Tj = Tbiv

3.43 kW

3.37 kW

COP Tj = Tbiv

2.36

1.78

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.08 kW

3.11 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.16

1.61

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

22 W

22 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2378 kWh

3287 kWh

Pdh Tj = -15°C (if TOL<-20°C)

3.27

1.88

COP Tj = -15°C (if TOL<-20°C)

2.55

1.88

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

29 dB(A)

29 dB(A)

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

183 %

131 %

Prated

4.40 kW

4.10 kW

SCOP

4.65

3.34

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.88 kW

3.57 kW

COP Tj = -7°C

3.07

2.16

Pdh Tj = +2°C

2.51 kW

2.34 kW

COP Tj = +2°C

4.69

3.29

Pdh Tj = +7°C

1.50 kW

2.13 kW

COP Tj = +7°C

5.78

4.29

Pdh Tj = 12°C

1.23 kW

2.52 kW

COP Tj = 12°C

6.13

5.53

Pdh Tj = Tbiv

4.37 kW

4.05 kW

COP Tj = Tbiv

2.76

1.85

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.37 kW

4.05 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.76

1.85

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

22 W

22 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1955 kWh

2533 kWh

Bosch Compress 6000 AW-5 AWM
Configure model
Model name
Bosch Compress 6000 AW-5 AWM
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

2.14 kW

1.88 kW

El input

0.46 kW

0.72 kW

COP

4.68

2.60

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

25 dB(A)

25 dB(A)

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

224 %

161 %

Prated

5.30 kW

5.60 kW

SCOP

5.69

4.10

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.28 kW

5.65 kW

COP Tj = +2°C

3.08

2.22

Pdh Tj = +7°C

3.22 kW

3.92 kW

COP Tj = +7°C

5.31

3.54

Pdh Tj = 12°C

1.50 kW

2.49 kW

COP Tj = 12°C

6.79

5.35

Pdh Tj = Tbiv

5.28 kW

5.65 kW

COP Tj = Tbiv

3.08

2.22

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.28 kW

5.65 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.08

2.22

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

22 W

22 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1245 kWh

1823 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

25 dB(A)

25 dB(A)

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

159 %

117 %

Prated

3.90 kW

4.00 kW

SCOP

4.04

3.00

Tbiv

-17 °C

-16 °C

TOL

-20 °C

-18 °C

Pdh Tj = -7°C

2.46 kW

2.32 kW

COP Tj = -7°C

3.56

2.57

Pdh Tj = +2°C

1.48 kW

1.79 kW

COP Tj = +2°C

4.86

3.66

Pdh Tj = +7°C

1.13 kW

2.13 kW

COP Tj = +7°C

5.53

4.54

Pdh Tj = 12°C

1.21 kW

2.55 kW

COP Tj = 12°C

5.75

5.82

Pdh Tj = Tbiv

3.43 kW

3.37 kW

COP Tj = Tbiv

2.36

1.78

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.08 kW

3.11 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.16

1.61

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

22 W

22 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.90 kW

4.00 kW

Annual energy consumption Qhe

2378 kWh

3287 kWh

Pdh Tj = -15°C (if TOL<-20°C)

3.27

1.88

COP Tj = -15°C (if TOL<-20°C)

2.55

1.88

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

25 dB(A)

25 dB(A)

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

183 %

131 %

Prated

4.40 kW

4.10 kW

SCOP

4.65

3.34

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.88 kW

3.57 kW

COP Tj = -7°C

3.07

2.16

Pdh Tj = +2°C

2.51 kW

2.34 kW

COP Tj = +2°C

4.69

3.29

Pdh Tj = +7°C

1.50 kW

2.13 kW

COP Tj = +7°C

5.78

4.29

Pdh Tj = 12°C

1.23 kW

2.52 kW

COP Tj = 12°C

6.13

5.53

Pdh Tj = Tbiv

4.37 kW

4.05 kW

COP Tj = Tbiv

2.76

1.85

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.37 kW

4.05 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.76

1.85

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

22 W

22 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1955 kWh

2533 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

119 %

COP

2.80

Heating up time

03:00 h:min

Standby power input

47.0 W

Reference hot water temperature

54.2 °C

Mixed water at 40°C

272 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

81 %

COP

1.90

Heating up time

04:18 h:min

Standby power input

65.0 W

Reference hot water temperature

52.4 °C

Mixed water at 40°C

275 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

96 %

COP

2.25

Heating up time

03:30 h:min

Standby power input

55.0 W

Reference hot water temperature

52.1 °C

Mixed water at 40°C

272 l

Bosch Compress 6000 AW-5 AWMS
Configure model
Model name
Bosch Compress 6000 AW-5 AWMS
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

2.14 kW

1.88 kW

El input

0.46 kW

0.72 kW

COP

4.68

2.60

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

25 dB(A)

25 dB(A)

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

224 %

161 %

Prated

5.30 kW

5.60 kW

SCOP

5.69

4.10

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.28 kW

5.65 kW

COP Tj = +2°C

3.08

2.22

Pdh Tj = +7°C

3.22 kW

3.92 kW

COP Tj = +7°C

5.31

3.54

Pdh Tj = 12°C

1.50 kW

2.49 kW

COP Tj = 12°C

6.79

5.35

Pdh Tj = Tbiv

5.28 kW

5.65 kW

COP Tj = Tbiv

3.08

2.22

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.28 kW

5.65 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.08

2.22

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

22 W

22 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1245 kWh

1823 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

25 dB(A)

25 dB(A)

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

159 %

117 %

Prated

3.90 kW

4.00 kW

SCOP

4.04

3.00

Tbiv

-17 °C

-16 °C

TOL

-20 °C

-18 °C

Pdh Tj = -7°C

2.46 kW

2.32 kW

COP Tj = -7°C

3.56

2.57

Pdh Tj = +2°C

1.48 kW

1.79 kW

COP Tj = +2°C

4.86

3.66

Pdh Tj = +7°C

1.13 kW

2.13 kW

COP Tj = +7°C

5.53

4.54

Pdh Tj = 12°C

1.21 kW

2.55 kW

COP Tj = 12°C

5.75

5.82

Pdh Tj = Tbiv

3.43 kW

3.37 kW

COP Tj = Tbiv

2.36

1.78

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.08 kW

3.11 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.16

1.61

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

22 W

22 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.90 kW

4.00 kW

Annual energy consumption Qhe

2378 kWh

3287 kWh

Pdh Tj = -15°C (if TOL<-20°C)

3.27

1.88

COP Tj = -15°C (if TOL<-20°C)

2.55

1.88

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

25 dB(A)

25 dB(A)

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

183 %

131 %

Prated

4.40 kW

4.10 kW

SCOP

4.65

3.34

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.88 kW

3.57 kW

COP Tj = -7°C

3.07

2.16

Pdh Tj = +2°C

2.51 kW

2.34 kW

COP Tj = +2°C

4.69

3.29

Pdh Tj = +7°C

1.50 kW

2.13 kW

COP Tj = +7°C

5.78

4.29

Pdh Tj = 12°C

1.23 kW

2.52 kW

COP Tj = 12°C

6.13

5.53

Pdh Tj = Tbiv

4.37 kW

4.05 kW

COP Tj = Tbiv

2.76

1.85

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.37 kW

4.05 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.76

1.85

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

22 W

22 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1955 kWh

2533 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

119 %

COP

2.80

Heating up time

03:00 h:min

Standby power input

47.0 W

Reference hot water temperature

54.2 °C

Mixed water at 40°C

272 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

81 %

COP

1.90

Heating up time

04:18 h:min

Standby power input

65.0 W

Reference hot water temperature

52.4 °C

Mixed water at 40°C

275 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

96 %

COP

2.25

Heating up time

03:30 h:min

Standby power input

55.0 W

Reference hot water temperature

52.1 °C

Mixed water at 40°C

272 l

Bosch CS7001iAW 5 ORE-S
Configure model
Model name
Bosch CS7001iAW 5 ORE-S
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

2.14 kW

1.88 kW

El input

0.46 kW

0.72 kW

COP

4.68

2.60

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

29 dB(A)

29 dB(A)

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

224 %

161 %

Prated

5.30 kW

5.60 kW

SCOP

5.69

4.10

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.28 kW

5.65 kW

COP Tj = +2°C

3.08

2.22

Pdh Tj = +7°C

3.22 kW

3.92 kW

COP Tj = +7°C

5.31

3.54

Pdh Tj = 12°C

1.50 kW

2.49 kW

COP Tj = 12°C

6.79

5.35

Pdh Tj = Tbiv

5.28 kW

5.65 kW

COP Tj = Tbiv

3.08

2.22

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.28 kW

5.65 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.08

2.22

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

22 W

22 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1245 kWh

1823 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

29 dB(A)

29 dB(A)

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

159 %

117 %

Prated

3.90 kW

4.00 kW

SCOP

4.04

3.00

Tbiv

-17 °C

-16 °C

TOL

-20 °C

-18 °C

Pdh Tj = -7°C

2.46 kW

2.32 kW

COP Tj = -7°C

3.56

2.57

Pdh Tj = +2°C

1.48 kW

1.79 kW

COP Tj = +2°C

4.86

3.66

Pdh Tj = +7°C

1.13 kW

2.13 kW

COP Tj = +7°C

5.53

4.54

Pdh Tj = 12°C

1.21 kW

2.55 kW

COP Tj = 12°C

5.75

5.82

Pdh Tj = Tbiv

3.43 kW

3.37 kW

COP Tj = Tbiv

2.36

1.78

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.08 kW

3.11 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.16

1.61

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

22 W

22 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.90 kW

4.00 kW

Annual energy consumption Qhe

2378 kWh

3287 kWh

Pdh Tj = -15°C (if TOL<-20°C)

3.27

1.88

COP Tj = -15°C (if TOL<-20°C)

2.55

1.88

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

29 dB(A)

29 dB(A)

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

183 %

131 %

Prated

4.40 kW

4.10 kW

SCOP

4.65

3.34

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.88 kW

3.57 kW

COP Tj = -7°C

3.07

2.16

Pdh Tj = +2°C

2.51 kW

2.34 kW

COP Tj = +2°C

4.69

3.29

Pdh Tj = +7°C

1.50 kW

2.13 kW

COP Tj = +7°C

5.78

4.29

Pdh Tj = 12°C

1.23 kW

2.52 kW

COP Tj = 12°C

6.13

5.53

Pdh Tj = Tbiv

4.37 kW

4.05 kW

COP Tj = Tbiv

2.76

1.85

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.37 kW

4.05 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.76

1.85

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

22 W

22 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1955 kWh

2533 kWh

Bosch CS7001iAW 5 ORB-S
Configure model
Model name
Bosch CS7001iAW 5 ORB-S
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

2.14 kW

1.88 kW

El input

0.46 kW

0.72 kW

COP

4.68

2.60

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

29 dB(A)

29 dB(A)

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

224 %

161 %

Prated

5.30 kW

5.60 kW

SCOP

5.69

4.10

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.28 kW

5.65 kW

COP Tj = +2°C

3.08

2.22

Pdh Tj = +7°C

3.22 kW

3.92 kW

COP Tj = +7°C

5.31

3.54

Pdh Tj = 12°C

1.50 kW

2.49 kW

COP Tj = 12°C

6.79

5.35

Pdh Tj = Tbiv

5.28 kW

5.65 kW

COP Tj = Tbiv

3.08

2.22

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.28 kW

5.65 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.08

2.22

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

22 W

22 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1245 kWh

1823 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

29 dB(A)

29 dB(A)

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

159 %

117 %

Prated

3.90 kW

4.00 kW

SCOP

4.04

3.00

Tbiv

-17 °C

-16 °C

TOL

-20 °C

-18 °C

Pdh Tj = -7°C

2.46 kW

2.32 kW

COP Tj = -7°C

3.56

2.57

Pdh Tj = +2°C

1.48 kW

1.79 kW

COP Tj = +2°C

4.86

3.66

Pdh Tj = +7°C

1.13 kW

2.13 kW

COP Tj = +7°C

5.53

4.54

Pdh Tj = 12°C

1.21 kW

2.55 kW

COP Tj = 12°C

5.75

5.82

Pdh Tj = Tbiv

3.43 kW

3.37 kW

COP Tj = Tbiv

2.36

1.78

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.08 kW

3.11 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.16

1.61

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

22 W

22 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2378 kWh

3287 kWh

Pdh Tj = -15°C (if TOL<-20°C)

3.27

1.88

COP Tj = -15°C (if TOL<-20°C)

2.55

1.88

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

29 dB(A)

29 dB(A)

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

183 %

131 %

Prated

4.40 kW

4.10 kW

SCOP

4.65

3.34

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.88 kW

3.57 kW

COP Tj = -7°C

3.07

2.16

Cdh Tj = -7 °C

1.00

1.00

Pdh Tj = +2°C

2.51 kW

2.34 kW

COP Tj = +2°C

4.69

3.29

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

1.50 kW

2.13 kW

COP Tj = +7°C

5.78

4.29

Cdh Tj = +7 °C

1.00

1.00

Pdh Tj = 12°C

1.23 kW

2.52 kW

COP Tj = 12°C

6.13

5.53

Cdh Tj = +12 °C

1.00

1.00

Pdh Tj = Tbiv

4.37 kW

4.05 kW

COP Tj = Tbiv

2.76

1.85

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.37 kW

4.05 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.76

1.85

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

22 W

22 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1955 kWh

2533 kWh

Bosch CS7001iAW 5 ORM-S
Configure model
Model name
Bosch CS7001iAW 5 ORM-S
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

2.14 kW

1.88 kW

El input

0.46 kW

0.72 kW

COP

4.68

2.60

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

25 dB(A)

25 dB(A)

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

224 %

161 %

Prated

5.30 kW

5.60 kW

SCOP

5.69

4.10

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.28 kW

5.65 kW

COP Tj = +2°C

3.08

2.22

Pdh Tj = +7°C

3.22 kW

3.92 kW

COP Tj = +7°C

5.31

3.54

Pdh Tj = 12°C

1.50 kW

2.49 kW

COP Tj = 12°C

6.79

5.35

Pdh Tj = Tbiv

5.28 kW

5.65 kW

COP Tj = Tbiv

3.08

2.22

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.28 kW

5.65 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.08

2.22

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

22 W

22 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1245 kWh

1823 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

25 dB(A)

25 dB(A)

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

159 %

117 %

Prated

3.90 kW

4.00 kW

SCOP

4.04

3.00

Tbiv

-17 °C

-16 °C

TOL

-20 °C

-18 °C

Pdh Tj = -7°C

2.46 kW

2.32 kW

COP Tj = -7°C

3.56

2.57

Pdh Tj = +2°C

1.48 kW

1.79 kW

COP Tj = +2°C

4.86

3.66

Pdh Tj = +7°C

1.13 kW

2.13 kW

COP Tj = +7°C

5.53

4.54

Pdh Tj = 12°C

1.21 kW

2.55 kW

COP Tj = 12°C

5.75

5.82

Pdh Tj = Tbiv

3.43 kW

3.37 kW

COP Tj = Tbiv

2.36

1.78

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.08 kW

3.11 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.16

1.61

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

22 W

22 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.90 kW

4.00 kW

Annual energy consumption Qhe

2378 kWh

3287 kWh

Pdh Tj = -15°C (if TOL<-20°C)

3.27

1.88

COP Tj = -15°C (if TOL<-20°C)

2.55

1.88

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

25 dB(A)

25 dB(A)

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

183 %

131 %

Prated

4.40 kW

4.10 kW

SCOP

4.65

3.34

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.88 kW

3.57 kW

COP Tj = -7°C

3.07

2.16

Pdh Tj = +2°C

2.51 kW

2.34 kW

COP Tj = +2°C

4.69

3.29

Pdh Tj = +7°C

1.50 kW

2.13 kW

COP Tj = +7°C

5.78

4.29

Pdh Tj = 12°C

1.23 kW

2.52 kW

COP Tj = 12°C

6.13

5.53

Pdh Tj = Tbiv

4.37 kW

4.05 kW

COP Tj = Tbiv

2.76

1.85

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.37 kW

4.05 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.76

1.85

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

22 W

22 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1955 kWh

2533 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

119 %

COP

2.80

Heating up time

03:00 h:min

Standby power input

47.0 W

Reference hot water temperature

54.2 °C

Mixed water at 40°C

272 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

81 %

COP

1.90

Heating up time

04:18 h:min

Standby power input

65.0 W

Reference hot water temperature

52.4 °C

Mixed water at 40°C

275 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

96 %

COP

2.25

Heating up time

03:30 h:min

Standby power input

55.0 W

Reference hot water temperature

52.1 °C

Mixed water at 40°C

272 l

Bosch CS7001iAW 5 ORMS-S
Configure model
Model name
Bosch CS7001iAW 5 ORMS-S
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

2.14 kW

1.88 kW

El input

0.46 kW

0.72 kW

COP

4.68

2.60

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

25 dB(A)

25 dB(A)

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

224 %

161 %

Prated

5.30 kW

5.60 kW

SCOP

5.69

4.10

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.28 kW

5.65 kW

COP Tj = +2°C

3.08

2.22

Pdh Tj = +7°C

3.22 kW

3.92 kW

COP Tj = +7°C

5.31

3.54

Pdh Tj = 12°C

1.50 kW

2.49 kW

COP Tj = 12°C

6.79

5.35

Pdh Tj = Tbiv

5.28 kW

5.65 kW

COP Tj = Tbiv

3.08

2.22

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.28 kW

5.65 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.08

2.22

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

22 W

22 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1245 kWh

1823 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

25 dB(A)

25 dB(A)

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

159 %

117 %

Prated

3.90 kW

4.00 kW

SCOP

4.04

3.00

Tbiv

-17 °C

-16 °C

TOL

-20 °C

-18 °C

Pdh Tj = -7°C

2.46 kW

2.32 kW

COP Tj = -7°C

3.56

2.57

Pdh Tj = +2°C

1.48 kW

1.79 kW

COP Tj = +2°C

4.86

3.66

Pdh Tj = +7°C

1.13 kW

2.13 kW

COP Tj = +7°C

5.53

4.54

Pdh Tj = 12°C

1.21 kW

2.55 kW

COP Tj = 12°C

5.75

5.82

Pdh Tj = Tbiv

3.43 kW

3.37 kW

COP Tj = Tbiv

2.36

1.78

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.08 kW

3.11 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.16

1.61

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

22 W

22 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.90 kW

4.00 kW

Annual energy consumption Qhe

2378 kWh

3287 kWh

Pdh Tj = -15°C (if TOL<-20°C)

3.27

1.88

COP Tj = -15°C (if TOL<-20°C)

2.55

1.88

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

25 dB(A)

25 dB(A)

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

183 %

131 %

Prated

4.40 kW

4.10 kW

SCOP

4.65

3.34

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.88 kW

3.57 kW

COP Tj = -7°C

3.07

2.16

Pdh Tj = +2°C

2.51 kW

2.34 kW

COP Tj = +2°C

4.69

3.29

Pdh Tj = +7°C

1.50 kW

2.13 kW

COP Tj = +7°C

5.78

4.29

Pdh Tj = 12°C

1.23 kW

2.52 kW

COP Tj = 12°C

6.13

5.53

Pdh Tj = Tbiv

4.37 kW

4.05 kW

COP Tj = Tbiv

2.76

1.85

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.37 kW

4.05 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.76

1.85

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

22 W

22 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1955 kWh

2533 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

119 %

COP

2.80

Heating up time

03:00 h:min

Standby power input

47.0 W

Reference hot water temperature

54.2 °C

Mixed water at 40°C

272 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

81 %

COP

1.90

Heating up time

04:18 h:min

Standby power input

65.0 W

Reference hot water temperature

52.4 °C

Mixed water at 40°C

275 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

96 %

COP

2.25

Heating up time

03:30 h:min

Standby power input

55.0 W

Reference hot water temperature

52.1 °C

Mixed water at 40°C

272 l

Bosch CSH7000iAW 5 OR
Configure model
Model name
Bosch CSH7000iAW 5 OR
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

2.14 kW

1.88 kW

El input

0.46 kW

0.72 kW

COP

4.68

2.60

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

29 dB(A)

29 dB(A)

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

224 %

161 %

Prated

5.30 kW

5.60 kW

SCOP

5.69

4.10

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.28 kW

5.65 kW

COP Tj = +2°C

3.08

2.22

Pdh Tj = +7°C

3.22 kW

3.92 kW

COP Tj = +7°C

5.31

3.54

Pdh Tj = 12°C

1.50 kW

2.49 kW

COP Tj = 12°C

6.79

5.35

Pdh Tj = Tbiv

5.28 kW

5.65 kW

COP Tj = Tbiv

3.08

2.22

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.28 kW

5.65 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.08

2.22

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

22 W

22 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1245 kWh

1823 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

29 dB(A)

29 dB(A)

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

159 %

117 %

Prated

3.90 kW

4.00 kW

SCOP

4.04

3.00

Tbiv

-17 °C

-16 °C

TOL

-20 °C

-18 °C

Pdh Tj = -7°C

2.46 kW

2.32 kW

COP Tj = -7°C

3.56

2.57

Pdh Tj = +2°C

1.48 kW

1.79 kW

COP Tj = +2°C

4.86

3.66

Pdh Tj = +7°C

1.13 kW

2.13 kW

COP Tj = +7°C

5.53

4.54

Pdh Tj = 12°C

1.21 kW

2.55 kW

COP Tj = 12°C

5.75

5.82

Pdh Tj = Tbiv

3.43 kW

3.37 kW

COP Tj = Tbiv

2.36

1.78

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.08 kW

3.11 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.16

1.61

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

22 W

22 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2378 kWh

3287 kWh

Pdh Tj = -15°C (if TOL<-20°C)

3.27

1.88

COP Tj = -15°C (if TOL<-20°C)

2.55

1.88

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

29 dB(A)

29 dB(A)

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

183 %

131 %

Prated

4.40 kW

4.10 kW

SCOP

4.65

3.34

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.88 kW

3.57 kW

COP Tj = -7°C

3.07

2.16

Pdh Tj = +2°C

2.51 kW

2.34 kW

COP Tj = +2°C

4.69

3.29

Pdh Tj = +7°C

1.50 kW

2.13 kW

COP Tj = +7°C

5.78

4.29

Pdh Tj = 12°C

1.23 kW

2.52 kW

COP Tj = 12°C

6.13

5.53

Pdh Tj = Tbiv

4.37 kW

4.05 kW

COP Tj = Tbiv

2.76

1.85

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.37 kW

4.05 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.76

1.85

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

22 W

22 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1955 kWh

2533 kWh

Bosch CS7001iAW 5 ORMB-S
Configure model
Model name
Bosch CS7001iAW 5 ORMB-S
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

2.14 kW

1.88 kW

El input

0.48 kW

0.75 kW

COP

4.44

2.52

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

49 dB(A)

49 dB(A)

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

208 %

153 %

Prated

5.30 kW

5.60 kW

SCOP

5.28

3.90

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.28 kW

5.65 kW

COP Tj = +2°C

2.98

2.19

Pdh Tj = +7°C

3.22 kW

3.92 kW

COP Tj = +7°C

5.01

3.45

Pdh Tj = 12°C

1.50 kW

2.49 kW

COP Tj = 12°C

6.19

5.05

Pdh Tj = Tbiv

5.28 kW

5.65 kW

COP Tj = Tbiv

2.98

2.19

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.28 kW

5.65 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.98

2.19

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

4 W

4 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1341 kWh

1918 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

49 dB(A)

49 dB(A)

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

150 %

112 %

Prated

3.90 kW

4.00 kW

SCOP

3.83

2.87

Tbiv

-17 °C

-16 °C

TOL

-20 °C

-18 °C

Pdh Tj = -7°C

2.46 kW

2.32 kW

COP Tj = -7°C

3.43

2.52

Pdh Tj = +2°C

1.48 kW

1.79 kW

COP Tj = +2°C

4.59

3.51

Pdh Tj = +7°C

1.13 kW

2.13 kW

COP Tj = +7°C

5.13

4.33

Pdh Tj = 12°C

1.21 kW

2.55 kW

COP Tj = 12°C

5.24

5.51

Pdh Tj = Tbiv

3.43 kW

3.37 kW

COP Tj = Tbiv

2.31

1.76

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.08 kW

3.11 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.12

1.59

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

4 W

4 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.90 kW

4.00 kW

Annual energy consumption Qhe

2511 kWh

3430 kWh

Pdh Tj = -15°C (if TOL<-20°C)

3.27

3.29

COP Tj = -15°C (if TOL<-20°C)

2.49

1.85

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

49 dB(A)

49 dB(A)

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

172 %

125 %

Prated

4.40 kW

4.10 kW

SCOP

4.39

3.20

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.88 kW

3.57 kW

COP Tj = -7°C

2.99

2.13

Pdh Tj = +2°C

2.51 kW

2.34 kW

COP Tj = +2°C

4.50

3.20

Pdh Tj = +7°C

1.50 kW

2.13 kW

COP Tj = +7°C

5.32

4.08

Pdh Tj = 12°C

1.23 kW

2.52 kW

COP Tj = 12°C

5.57

5.22

Pdh Tj = Tbiv

4.37 kW

4.05 kW

COP Tj = Tbiv

2.70

1.83

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.37 kW

4.05 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.70

1.83

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

4 W

4 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2072 kWh

2647 kWh