2,300 kg
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
kW
kW
Cooling capacity
EER
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
9.00 kW
9.00 kW
El input
1.86 kW
3.06 kW
COP
4.84
2.94
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
dB(A)
dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
235 %
158 %
Prated
9.00 kW
9.00 kW
SCOP
5.95
4.02
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
8.90 kW
9.00 kW
COP Tj = +2°C
3.49
2.39
Cdh Tj = +2 °C
1.000
1.000
Pdh Tj = +7°C
5.70 kW
5.70 kW
COP Tj = +7°C
5.49
3.33
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
6.00 kW
5.30 kW
COP Tj = 12°C
7.29
5.35
Cdh Tj = +12 °C
0.990
0.990
Pdh Tj = Tbiv
8.90 kW
9.00 kW
COP Tj = Tbiv
3.49
2.39
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.90 kW
9.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.49
2.39
WTOL
55 °C
55 °C
Poff
3 W
3 W
PTO
12 W
12 W
PSB
12 W
12 W
PCK
33 W
33 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.10 kW
0.00 kW
Annual energy consumption Qhe
2020 kWh
2991 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
dB(A)
dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
160 %
125 %
Prated
11.00 kW
11.00 kW
SCOP
4.08
3.20
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
6.70 kW
6.50 kW
COP Tj = -7°C
3.28
2.56
Cdh Tj = -7 °C
0.990
1.000
Pdh Tj = +2°C
4.30 kW
4.00 kW
COP Tj = +2°C
4.99
3.91
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
5.00 kW
4.80 kW
COP Tj = +7°C
6.29
4.99
Cdh Tj = +7 °C
0.980
0.990
Pdh Tj = 12°C
5.80 kW
5.70 kW
COP Tj = 12°C
7.45
6.32
Cdh Tj = +12 °C
0.980
0.990
Pdh Tj = Tbiv
9.20 kW
8.90 kW
COP Tj = Tbiv
2.48
1.93
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.80 kW
8.90 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.85
1.52
WTOL
55 °C
55 °C
Poff
3 W
3 W
PTO
12 W
12 W
PSB
12 W
12 W
PCK
33 W
33 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.20 kW
2.10 kW
Annual energy consumption Qhe
6651 kWh
8468 kWh
Pdh Tj = -15°C (if TOL<-20°C)
9.20
8.90
COP Tj = -15°C (if TOL<-20°C)
2.48
1.93
Cdh Tj = -15 °C
1.000
1.000
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
dB(A)
dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
181 %
130 %
Prated
9.00 kW
9.00 kW
SCOP
4.59
3.32
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.50 kW
7.70 kW
COP Tj = -7°C
2.75
2.11
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
4.70 kW
4.80 kW
COP Tj = +2°C
4.57
3.24
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
5.00 kW
4.60 kW
COP Tj = +7°C
5.89
4.17
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
6.10 kW
5.50 kW
COP Tj = 12°C
7.67
5.74
Cdh Tj = +12 °C
0.980
0.990
Pdh Tj = Tbiv
9.00 kW
8.70 kW
COP Tj = Tbiv
2.71
2.00
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.00 kW
8.70 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.71
2.00
WTOL
55 °C
55 °C
Poff
3 W
3 W
PTO
12 W
12 W
PSB
12 W
12 W
PCK
33 W
33 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.30 kW
Annual energy consumption Qhe
4049 kWh
5596 kWh
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
3.56 kW
1.95 kW
Cooling capacity
10.00
10.00
EER
2.81
5.13
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
12.00 kW
12.00 kW
El input
2.53 kW
4.16 kW
COP
4.74
2.88
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
dB(A)
dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
231 %
158 %
Prated
12.00 kW
12.00 kW
SCOP
5.86
4.02
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
11.90 kW
11.70 kW
COP Tj = +2°C
3.18
2.15
Cdh Tj = +2 °C
1.000
1.000
Pdh Tj = +7°C
7.60 kW
7.80 kW
COP Tj = +7°C
5.25
3.33
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
5.90 kW
5.70 kW
COP Tj = 12°C
7.33
5.39
Cdh Tj = +12 °C
0.990
0.990
Pdh Tj = Tbiv
11.90 kW
11.70 kW
COP Tj = Tbiv
3.18
2.15
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.90 kW
11.70 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.18
2.15
WTOL
55 °C
55 °C
Poff
3 W
3 W
PTO
12 W
12 W
PSB
12 W
12 W
PCK
33 W
33 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.10 kW
0.30 kW
Annual energy consumption Qhe
2738 kWh
3990 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
dB(A)
dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
160 %
125 %
Prated
14.00 kW
13.00 kW
SCOP
4.08
3.20
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
8.40 kW
7.90 kW
COP Tj = -7°C
3.20
2.54
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
5.00 kW
4.10 kW
COP Tj = +2°C
5.09
3.97
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
5.10 kW
4.80 kW
COP Tj = +7°C
6.61
4.89
Cdh Tj = +7 °C
0.980
0.990
Pdh Tj = 12°C
5.90 kW
5.60 kW
COP Tj = 12°C
7.99
6.00
Cdh Tj = +12 °C
0.980
0.990
Pdh Tj = Tbiv
11.20 kW
10.40 kW
COP Tj = Tbiv
2.48
1.94
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.90 kW
8.90 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.92
1.50
WTOL
55 °C
55 °C
Poff
3 W
3 W
PTO
12 W
12 W
PSB
12 W
12 W
PCK
33 W
33 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
3.10 kW
4.10 kW
Annual energy consumption Qhe
8460 kWh
10012 kWh
Pdh Tj = -15°C (if TOL<-20°C)
11.20
10.40
COP Tj = -15°C (if TOL<-20°C)
2.48
1.94
Cdh Tj = -15 °C
1.000
1.000
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
dB(A)
dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
170 %
130 %
Prated
12.00 kW
12.00 kW
SCOP
4.32
3.32
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.70 kW
10.80 kW
COP Tj = -7°C
2.84
2.03
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
6.70 kW
6.10 kW
COP Tj = +2°C
3.96
3.19
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
5.10 kW
4.70 kW
COP Tj = +7°C
5.93
4.38
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
6.00 kW
5.70 kW
COP Tj = 12°C
7.88
5.89
Cdh Tj = +12 °C
0.980
0.990
Pdh Tj = Tbiv
12.00 kW
11.70 kW
COP Tj = Tbiv
2.56
1.95
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.00 kW
11.70 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.56
1.95
WTOL
55 °C
55 °C
Poff
3 W
3 W
PTO
12 W
12 W
PSB
12 W
12 W
PCK
33 W
33 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.00 kW
0.30 kW
Annual energy consumption Qhe
5745 kWh
7466 kWh
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
kW
kW
Cooling capacity
EER
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
9.00 kW
9.00 kW
El input
1.86 kW
3.06 kW
COP
4.84
2.94
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
dB(A)
dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
235 %
158 %
Prated
9.00 kW
9.00 kW
SCOP
5.95
4.02
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
8.90 kW
9.00 kW
COP Tj = +2°C
3.49
2.39
Cdh Tj = +2 °C
1.000
1.000
Pdh Tj = +7°C
5.70 kW
5.70 kW
COP Tj = +7°C
5.49
3.33
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
6.00 kW
5.30 kW
COP Tj = 12°C
7.29
5.35
Cdh Tj = +12 °C
0.990
0.990
Pdh Tj = Tbiv
8.90 kW
9.00 kW
COP Tj = Tbiv
3.49
2.39
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.90 kW
9.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.49
2.39
WTOL
55 °C
55 °C
Poff
3 W
3 W
PTO
12 W
12 W
PSB
12 W
12 W
PCK
33 W
33 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.10 kW
0.00 kW
Annual energy consumption Qhe
2020 kWh
2991 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
dB(A)
dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
160 %
125 %
Prated
11.00 kW
11.00 kW
SCOP
4.08
3.20
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
6.70 kW
6.50 kW
COP Tj = -7°C
3.28
2.56
Cdh Tj = -7 °C
0.990
1.000
Pdh Tj = +2°C
4.30 kW
4.00 kW
COP Tj = +2°C
4.99
3.91
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
5.00 kW
4.80 kW
COP Tj = +7°C
6.29
4.99
Cdh Tj = +7 °C
0.980
0.990
Pdh Tj = 12°C
5.80 kW
5.70 kW
COP Tj = 12°C
7.45
6.32
Cdh Tj = +12 °C
0.980
0.990
Pdh Tj = Tbiv
9.20 kW
8.90 kW
COP Tj = Tbiv
2.48
1.93
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.80 kW
8.90 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.85
1.52
WTOL
55 °C
55 °C
Poff
3 W
3 W
PTO
12 W
12 W
PSB
12 W
12 W
PCK
33 W
33 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
1.20 kW
2.10 kW
Annual energy consumption Qhe
6651 kWh
8468 kWh
Pdh Tj = -15°C (if TOL<-20°C)
9.20
8.90
COP Tj = -15°C (if TOL<-20°C)
2.48
1.93
Cdh Tj = -15 °C
1.000
1.000
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
dB(A)
dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
181 %
130 %
Prated
9.00 kW
9.00 kW
SCOP
4.59
3.32
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.50 kW
7.70 kW
COP Tj = -7°C
2.75
2.11
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
4.70 kW
4.80 kW
COP Tj = +2°C
4.57
3.24
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
5.00 kW
4.60 kW
COP Tj = +7°C
5.89
4.17
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
6.10 kW
5.50 kW
COP Tj = 12°C
7.67
5.74
Cdh Tj = +12 °C
0.980
0.990
Pdh Tj = Tbiv
9.00 kW
8.70 kW
COP Tj = Tbiv
2.71
2.00
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.00 kW
8.70 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.71
2.00
WTOL
55 °C
55 °C
Poff
3 W
3 W
PTO
12 W
12 W
PSB
12 W
12 W
PCK
33 W
33 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.00 kW
0.30 kW
Annual energy consumption Qhe
4049 kWh
5596 kWh
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
3.56 kW
1.95 kW
Cooling capacity
10.00
10.00
EER
2.81
5.13
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
12.00 kW
12.00 kW
El input
2.53 kW
4.16 kW
COP
4.74
2.88
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
dB(A)
dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
231 %
158 %
Prated
12.00 kW
12.00 kW
SCOP
5.86
4.02
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
11.90 kW
11.70 kW
COP Tj = +2°C
3.18
2.15
Cdh Tj = +2 °C
1.000
1.000
Pdh Tj = +7°C
7.60 kW
7.80 kW
COP Tj = +7°C
5.25
3.33
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
5.90 kW
5.70 kW
COP Tj = 12°C
7.33
5.39
Cdh Tj = +12 °C
0.990
0.990
Pdh Tj = Tbiv
11.90 kW
11.70 kW
COP Tj = Tbiv
3.18
2.15
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.90 kW
11.70 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.18
2.15
WTOL
55 °C
55 °C
Poff
3 W
3 W
PTO
12 W
12 W
PSB
12 W
12 W
PCK
33 W
33 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.10 kW
0.30 kW
Annual energy consumption Qhe
2738 kWh
3990 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
dB(A)
dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
160 %
125 %
Prated
14.00 kW
13.00 kW
SCOP
4.08
3.20
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
8.40 kW
7.90 kW
COP Tj = -7°C
3.20
2.54
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
5.00 kW
4.10 kW
COP Tj = +2°C
5.09
3.97
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
5.10 kW
4.80 kW
COP Tj = +7°C
6.61
4.89
Cdh Tj = +7 °C
0.980
0.990
Pdh Tj = 12°C
5.90 kW
5.60 kW
COP Tj = 12°C
7.99
6.00
Cdh Tj = +12 °C
0.980
0.990
Pdh Tj = Tbiv
11.20 kW
10.40 kW
COP Tj = Tbiv
2.48
1.94
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.90 kW
8.90 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.92
1.50
WTOL
55 °C
55 °C
Poff
3 W
3 W
PTO
12 W
12 W
PSB
12 W
12 W
PCK
33 W
33 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.10 kW
4.10 kW
Annual energy consumption Qhe
8460 kWh
10012 kWh
Pdh Tj = -15°C (if TOL<-20°C)
11.20
10.40
COP Tj = -15°C (if TOL<-20°C)
2.48
1.94
Cdh Tj = -15 °C
1.000
1.000
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
dB(A)
dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
170 %
130 %
Prated
12.00 kW
12.00 kW
SCOP
4.32
3.32
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.70 kW
10.80 kW
COP Tj = -7°C
2.84
2.03
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
6.70 kW
6.10 kW
COP Tj = +2°C
3.96
3.19
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
5.10 kW
4.70 kW
COP Tj = +7°C
5.93
4.38
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
6.00 kW
5.70 kW
COP Tj = 12°C
7.88
5.89
Cdh Tj = +12 °C
0.980
0.990
Pdh Tj = Tbiv
12.00 kW
11.70 kW
COP Tj = Tbiv
2.56
1.95
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.00 kW
11.70 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.56
1.95
WTOL
55 °C
55 °C
Poff
3 W
3 W
PTO
12 W
12 W
PSB
12 W
12 W
PCK
33 W
33 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.30 kW
Annual energy consumption Qhe
5745 kWh
7466 kWh