1,500 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
2.42 kW
1.57 kW
El input
0.50 kW
0.76 kW
COP
4.85
2.06
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
35 dB(A)
35 dB(A)
Sound power level outdoor
50 dB(A)
50 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
188 %
131 %
Prated
4.80 kW
5.30 kW
SCOP
4.77
3.35
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.30 kW
4.70 kW
COP Tj = -7°C
2.60
1.88
Pdh Tj = +2°C
2.60 kW
2.80 kW
COP Tj = +2°C
4.84
3.26
Pdh Tj = +7°C
1.70 kW
1.80 kW
COP Tj = +7°C
6.91
4.72
Pdh Tj = 12°C
2.70 kW
2.70 kW
COP Tj = 12°C
7.72
6.47
Pdh Tj = Tbiv
4.30 kW
4.70 kW
COP Tj = Tbiv
2.60
1.88
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.20 kW
4.10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.24
1.77
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.98
0.99
WTOL
58 °C
58 °C
Poff
7 W
7 W
PTO
12 W
12 W
PSB
12 W
12 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.60 kW
1.20 kW
Annual energy consumption Qhe
2089 kWh
3248 kWh