THERMA V High temperature 3rd Gen 16kW

Certificate Holder
LG Electronics Inc.
84, Wanam-ro, seongsan-gu
51554 Changwon-si
South Korea
Registration number
011-1W0336
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
THERMA V High temperature 3rd Gen 16kW
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R410A
Mass of Refrigerant

3,800 kg

Certification Date
28.06.2019
Testing basis
n/a
Generate PDF Export model CSV
  • Number of models 1

Models

HU161HA U33, HN1610H NK3
Configure model
Model name
HU161HA U33, HN1610H NK3
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.00 kW

14.00 kW

El input

4.89 kW

5.04 kW

COP

3.27

2.78

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

63 dB(A)

63 dB(A)

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

126 %

117 %

Prated

13.00 kW

11.00 kW

SCOP

3.23

3.01

Tbiv

-10 °C

-10 °C

TOL

-15 °C

-15 °C

Pdh Tj = -7°C

11.90 kW

9.60 kW

COP Tj = -7°C

2.40

2.46

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

7.00 kW

5.90 kW

COP Tj = +2°C

3.30

3.47

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

4.70 kW

3.70 kW

COP Tj = +7°C

4.20

3.00

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

4.80 kW

4.50 kW

COP Tj = 12°C

3.80

3.60

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

13.50 kW

10.80 kW

COP Tj = Tbiv

2.10

2.00

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.50 kW

10.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.10

2.00

WTOL

65 °C

65 °C

Poff

60 W

60 W

PTO

60 W

60 W

PSB

60 W

60 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

Electricity

Supplementary Heater: PSUP

0.00 kW

0.20 kW

Annual energy consumption Qhe

8618 kWh

7424 kWh