2,500 kg
Heating
EN 14511-4
Operating range outdoor exchanger/indoor exchanger lower limit/lower limit
passed
Operating range outdoor exchanger/indoor exchanger upper limit/upper limit
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
13.00 kW
10.60 kW
El input
3.11 kW
4.40 kW
COP
4.18
2.41
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
46 dB(A)
46 dB(A)
Sound power level outdoor
69 dB(A)
69 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
150 %
117 %
Prated
12.50 kW
11.30 kW
SCOP
3.82
3.00
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
11.10 kW
10.00 kW
COP Tj = -7°C
2.50
2.00
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
6.70 kW
6.10 kW
COP Tj = +2°C
3.70
2.90
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
6.20 kW
5.90 kW
COP Tj = +7°C
5.40
4.10
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
7.30 kW
7.10 kW
COP Tj = 12°C
7.00
5.40
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
11.10 kW
10.00 kW
COP Tj = Tbiv
2.50
2.00
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.80 kW
9.30 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.40
1.60
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
66 W
43 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.70 kW
2.00 kW
Annual energy consumption Qhe
6738 kWh
7803 kWh