2,500 kg
Heating
EN 14511-4
Operating range outdoor exchanger/indoor exchanger lower limit/lower limit
passed
Operating range outdoor exchanger/indoor exchanger upper limit/upper limit
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
10.80 kW
9.29 kW
El input
2.51 kW
3.52 kW
COP
4.30
2.64
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
46 dB(A)
46 dB(A)
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
154 %
112 %
Prated
11.30 kW
9.30 kW
SCOP
3.92
2.87
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.00 kW
8.20 kW
COP Tj = -7°C
2.70
1.90
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
6.10 kW
5.00 kW
COP Tj = +2°C
3.70
2.70
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
6.20 kW
5.90 kW
COP Tj = +7°C
5.50
3.90
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
7.40 kW
7.00 kW
COP Tj = 12°C
7.10
5.20
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
10.00 kW
8.20 kW
COP Tj = Tbiv
2.70
1.90
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.90 kW
8.10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.30
1.60
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
44 W
32 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.40 kW
1.20 kW
Annual energy consumption Qhe
5930 kWh
6669 kWh