2,200 kg
Heating
EN 14511-4
Operating range outdoor exchanger/indoor exchanger lower limit/lower limit
passed
Operating range outdoor exchanger/indoor exchanger upper limit/upper limit
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
6.21 kW
5.76 kW
El input
1.39 kW
2.07 kW
COP
4.46
2.79
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
60 dB(A)
60 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
154 %
116 %
Prated
6.00 kW
5.80 kW
SCOP
3.90
3.00
Tbiv
-17 °C
-17 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
3.70 kW
3.60 kW
COP Tj = -7°C
3.16
2.45
Cdh Tj = -7 °C
Pdh Tj = +2°C
2.20 kW
2.10 kW
COP Tj = +2°C
5.08
3.80
Cdh Tj = +2 °C
Pdh Tj = +7°C
2.60 kW
2.50 kW
COP Tj = +7°C
6.27
4.95
Cdh Tj = +7 °C
Pdh Tj = 12°C
2.90 kW
2.90 kW
COP Tj = 12°C
7.59
6.44
Cdh Tj = +12 °C
Pdh Tj = Tbiv
5.10 kW
4.70 kW
COP Tj = Tbiv
2.49
1.80
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.90 kW
4.80 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.91
1.56
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.970
0.980
WTOL
65 °C
65 °C
Poff
15 W
15 W
PTO
9 W
9 W
PSB
15 W
15 W
PCK
23 W
23 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.10 kW
1.05 kW
Annual energy consumption Qhe
3780 kWh
4791 kWh
Pdh Tj = -15°C (if TOL<-20°C)
5.06
4.73
COP Tj = -15°C (if TOL<-20°C)
2.49
1.80
Cdh Tj = -15 °C
0.988
0.992
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
60 dB(A)
60 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
171 %
125 %
Prated
4.30 kW
8.00 kW
SCOP
4.40
3.20
Tbiv
-10 °C
-8 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
3.90 kW
7.00 kW
COP Tj = -7°C
2.92
7.95
Cdh Tj = -7 °C
Pdh Tj = +2°C
2.50 kW
4.40 kW
COP Tj = +2°C
4.70
3.14
Cdh Tj = +2 °C
Pdh Tj = +7°C
2.60 kW
2.80 kW
COP Tj = +7°C
5.93
4.63
Cdh Tj = +7 °C
Pdh Tj = 12°C
1.30 kW
2.90 kW
COP Tj = 12°C
7.59
6.17
Cdh Tj = +12 °C
Pdh Tj = Tbiv
4.30 kW
7.20 kW
COP Tj = Tbiv
2.62
1.84
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.30 kW
6.10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.62
1.71
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.970
0.980
WTOL
65 °C
65 °C
Poff
15 W
15 W
PTO
9 W
9 W
PSB
15 W
15 W
PCK
23 W
23 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
1.90 kW
Annual energy consumption Qhe
2005 kWh
5155 kWh