3,500 kg
Heating
EN 14511-4
Operating range outdoor exchanger/indoor exchanger lower limit/lower limit
passed
Operating range outdoor exchanger/indoor exchanger upper limit/upper limit
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
18.72 kW
15.94 kW
El input
4.05 kW
5.45 kW
COP
4.62
2.92
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
66 dB(A)
66 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
129 %
107 %
Prated
11.91 kW
11.14 kW
SCOP
3.30
2.80
Tbiv
-14 °C
-14 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
11.60 kW
11.00 kW
COP Tj = -7°C
3.20
2.52
Pdh Tj = +2°C
14.10 kW
13.60 kW
COP Tj = +2°C
3.84
3.15
Pdh Tj = +7°C
17.80 kW
17.40 kW
COP Tj = +7°C
4.74
4.01
Pdh Tj = 12°C
21.30 kW
20.50 kW
COP Tj = 12°C
5.54
4.76
Pdh Tj = Tbiv
9.10 kW
8.50 kW
COP Tj = Tbiv
2.63
1.98
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.80 kW
6.10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.04
1.44
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.98
0.99
WTOL
65 °C
65 °C
Poff
18 W
18 W
PTO
68 W
20 W
PSB
18 W
18 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
5.00 kW
4.90 kW
Annual energy consumption Qhe
8876 kWh
9970 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
66 dB(A)
66 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
145 %
119 %
Prated
13.88 kW
14.20 kW
SCOP
3.70
3.10
Tbiv
-6 °C
-5 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
11.50 kW
10.90 kW
COP Tj = -7°C
3.07
2.35
Pdh Tj = +2°C
14.00 kW
13.40 kW
COP Tj = +2°C
3.72
2.97
Pdh Tj = +7°C
17.70 kW
17.30 kW
COP Tj = +7°C
4.64
3.81
Pdh Tj = 12°C
21.40 kW
20.30 kW
COP Tj = 12°C
5.56
4.62
Pdh Tj = Tbiv
11.50 kW
11.50 kW
COP Tj = Tbiv
3.15
2.49
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.50 kW
10.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.82
2.10
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.98
0.99
WTOL
65 °C
65 °C
Poff
18 W
18 W
PTO
68 W
20 W
PSB
18 W
18 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.40 kW
4.30 kW
Annual energy consumption Qhe
7739 kWh
9646 kWh