2,500 kg
Heating
EN 14511-4
Operating range outdoor exchanger/indoor exchanger lower limit/lower limit
passed
Operating range outdoor exchanger/indoor exchanger upper limit/upper limit
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
14.01 kW
7.84 kW
El input
3.50 kW
3.25 kW
COP
4.00
2.41
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
46 dB(A)
46 dB(A)
Sound power level outdoor
69 dB(A)
69 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
151 %
109 %
Prated
11.00 kW
8.00 kW
SCOP
3.85
2.80
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.00 kW
8.20 kW
COP Tj = -7°C
2.60
1.90
Pdh Tj = +2°C
6.10 kW
5.00 kW
COP Tj = +2°C
3.70
2.70
Pdh Tj = +7°C
6.20 kW
5.90 kW
COP Tj = +7°C
5.30
3.80
Pdh Tj = 12°C
7.40 kW
7.00 kW
COP Tj = 12°C
6.90
4.80
Pdh Tj = Tbiv
10.00 kW
8.20 kW
COP Tj = Tbiv
2.60
1.90
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.00 kW
8.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.20
1.70
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.90
0.90
WTOL
55 °C
55 °C
Poff
8 W
8 W
PTO
45 W
22 W
PSB
12 W
12 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.30 kW
1.30 kW
Annual energy consumption Qhe
6062 kWh
6842 kWh