DAIKIN ALTHERMA 3 M 8kW
Heat Pump Type: Outdoor Air/Water
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
7.5 kW
7.5 kW
El input
1.63 kW
2.78 kW
COP
4.6
2.7
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
El input
1.73 kW
Cooling capacity
5.44
EER
3.14
EN 14825
+7°C/+12°C
Pdesignc
5.4 kW
SEER
5.36
Pdc Tj = 35°C
5.44 kW
EER Tj = 35°C
3.14
Pdc Tj = 30°C
4.02 kW
EER Tj = 30°C
4.66
Cdc Tj = 30 °C
1
Pdc Tj = 25°C
2.47 kW
EER Tj = 25°C
6.21
Cdc Tj = 25 °C
1
Pdc Tj = 20°C
2.54 kW
EER Tj = 20°C
7.17
Cdc Tj = 20 °C
1
Poff
10 W
PTO
10 W
PSB
10 W
PCK
0 W
Annual energy consumption Qce
609 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
257 %
159 %
Prated
7 kW
8.1 kW
SCOP
6.51
4.05
Tbiv
2 °C
4 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
7 kW
6.8 kW
COP Tj = +2°C
3.28
2.09
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
4.5 kW
5.3 kW
COP Tj = +7°C
5.95
3.42
Cdh Tj = +7 °C
1
1
Pdh Tj = 12°C
3.3 kW
2.8 kW
COP Tj = 12°C
8.57
5.52
Cdh Tj = +12 °C
1
1
Pdh Tj = Tbiv
7 kW
6.9 kW
COP Tj = Tbiv
3.28
2.66
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7 kW
8.1 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.28
2.09
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
35 °C
55 °C
Poff
10 W
10 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
1437 kWh
2669 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
179 %
130 %
Prated
8 kW
8 kW
SCOP
4.56
3.32
Tbiv
-8 °C
-8 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7 kW
6.9 kW
COP Tj = -7°C
2.77
1.96
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
4.2 kW
4.4 kW
COP Tj = +2°C
4.35
3.2
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
3.3 kW
3.3 kW
COP Tj = +7°C
6.49
4.64
Cdh Tj = +7 °C
1
1
Pdh Tj = 12°C
3.9 kW
4.1 kW
COP Tj = 12°C
8.52
6.22
Cdh Tj = +12 °C
1
1
Pdh Tj = Tbiv
7.5 kW
7.5 kW
COP Tj = Tbiv
2.66
1.9
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.93 kW
7.05 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.41
1.64
WTOL
35 °C
55 °C
Poff
10 W
10 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.07 kW
0.95 kW
Annual energy consumption Qhe
3625 kWh
4975 kWh