Login

Single View for Model

Subtype

DAIKIN ALTHERMA 3 M 11kW

Heat Pump Type: Outdoor Air/Water

Applicant

DAIKIN Europe N.V.
Zandvoordestraat 300
B-8400 Oostende
Belgium

Certification Body

DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Alboinstr. 56
12103 Berlin
Germany

EDLA11D(3)W1

Configure model
Model name
EDLA11D(3)W1
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

10.56 kW

10.64 kW

El input

2.19 kW

3.62 kW

COP

4.83

2.94

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

3.56 kW

Cooling capacity

11.59

EER

3.26

EN 14825

+7°C/+12°C

Pdesignc

11.50 kW

SEER

5.79

Pdc Tj = 35°C

11.60 kW

EER Tj = 35°C

3.26

Pdc Tj = 30°C

8.80 kW

EER Tj = 30°C

4.75

Cdc Tj = 30 °C

1.0

Pdc Tj = 25°C

5.70 kW

EER Tj = 25°C

6.91

Cdc Tj = 25 °C

1.0

Pdc Tj = 20°C

5.80 kW

EER Tj = 20°C

8.45

Cdc Tj = 20 °C

1.0

Poff

23 W

PTO

23 W

PSB

23 W

PCK

0 W

Annual energy consumption Qce

1190 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

237 %

165 %

Prated

10.00 kW

10.00 kW

SCOP

5.99

4.19

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

10.30 kW

9.80 kW

COP Tj = +2°C

3.30

2.18

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

6.70 kW

6.20 kW

COP Tj = +7°C

5.70

3.74

Cdh Tj = +7 °C

1.00

1.00

Pdh Tj = 12°C

5.20 kW

5.00 kW

COP Tj = 12°C

7.87

5.68

Cdh Tj = +12 °C

1.00

1.00

Pdh Tj = Tbiv

10.30 kW

9.80 kW

COP Tj = Tbiv

3.30

2.18

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.30 kW

9.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.30

2.18

WTOL

35 °C

55 °C

Poff

23 W

23 W

PTO

23 W

23 W

PSB

23 W

23 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2230 kWh

3184 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

182 %

130 %

Prated

10.00 kW

10.00 kW

SCOP

4.64

3.32

Tbiv

-10 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

9.20 kW

9.30 kW

COP Tj = -7°C

3.03

1.90

Cdh Tj = -7 °C

 

1.00

Pdh Tj = +2°C

5.50 kW

5.40 kW

COP Tj = +2°C

4.37

3.25

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

4.60 kW

4.40 kW

COP Tj = +7°C

6.74

4.81

Cdh Tj = +7 °C

1.00

1.00

Pdh Tj = 12°C

5.40 kW

5.30 kW

COP Tj = 12°C

8.54

6.41

Cdh Tj = +12 °C

1.00

1.00

Pdh Tj = Tbiv

10.10 kW

9.30 kW

COP Tj = Tbiv

2.58

1.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.10 kW

7.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.58

1.64

WTOL

35 °C

55 °C

Poff

23 W

23 W

PTO

23 W

23 W

PSB

23 W

23 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

2.40 kW

Annual energy consumption Qhe

4456 kWh

6281 kWh